Results 41 to 50 of about 11,324 (226)
Low Noise Low Power CMOS Telescopic-OTA for Bio-Medical Applications
The preamplifier block is crucial in bio-medical signal processing. The power intensive Operational Transconductance Amplifier (OTA) is considered, and the performance of preamplifier is studied.
Bellamkonda Saidulu +2 more
doaj +1 more source
Pyroelectric USB-joulemeters of pulsed laser radiation
The general arrangement, principle of operation and basic parameters of pyroelectric USB-meters of energy of pulsed laser radiation have been described. A smart head of the meter converts the signal from the pyroelectric sensor and immediately transfers ...
V.B. Samoylov +4 more
doaj +1 more source
Compact Tabletop Magnetic Resonance Elastography for Mapping Soft Tissue Viscoelasticity
This work introduces a compact, low‐cost tabletop magnetic resonance elastography platform for high‐resolution viscoelastic mapping in soft‐tissue specimens. Using this method in human colorectal liver metastases, we demonstrate fully automated biomechanical profiling of treatment response and show that heterogeneity‐based metrics outperform ...
Weijie Zhao +19 more
wiley +1 more source
Full exploitation of the intrinsic fast timing capabilities of analog silicon photomultipliers (SiPMs) requires suitable front-end electronics. Even a parasitic inductance of a few nH, associated to the interconnections between the SiPM and the ...
Pietro Antonio Paolo Calò +3 more
doaj +1 more source
An Energy Autonomous Microneedle Array‐Based Sensing System for Continuous Biomarker Monitoring
This work presents an innovative self‐powered wearable biosensor system for real‐time monitoring of multiple biomarkers in interstitial fluid. The device integrates stainless steel‐based minimally invasive microneedles with ion‐selective membranes, enabling simultaneous Na+, K+, Ca2+, pH, and glucose detection.
Arnab Pal +9 more
wiley +1 more source
Particle Mass Spectrometer (PMS) and its Application to Nano-Particle Sizing in Various Systems
Particle mass spectrometry has been shown to be an effective diagnostic technique to determine particle size and size distribution of charged nano-particles originating from different reactive sources. In the present
Christian Janzen +2 more
doaj +1 more source
A dual‐interface strategy combining a solvent‐orthogonal Poly‐TPD buffer with UV–ozone tuning of PbS‐EDT reconstructs interfacial energetics and defect chemistry in PbS CQD photodiodes. The optimized interface suppresses shunt‐ and trap‐related leakage, reduces noise, and enables high‐detectivity near‐infrared detection with imaging capability ...
Chuan Wei +8 more
wiley +1 more source
A New Preamplifier for Particle Detectors [PDF]
A new preamplifier for particle detectors has been designed and built for the Fermilab VTPC by Fujitsu of Japan. The device, designated MB43458, is a semi-custom monolithic assembled in a small, low mass package. The purpose of this report is to document the preliminary tests which have been done thus far.
openaire +2 more sources
We report the solid‐state ball milling, a traditional, reliable, mass‐productive material processing, to prepare the air‐stable and dual‐phase GeSe2‐x nanoparticles with extended photodetection feasibility toward optical‐wavelength regions. We further display photonic multi‐valued logic (MVL) circuit through the employment of a hybrid PMMA/GeSe2‐x ...
An‐Ting Tsai +8 more
wiley +1 more source
Recent Results on the Optoelectronic Feedback Preamplifier [PDF]
A brief description of the optoelectronic feedback system is followed by an account of some interesting aspects of low-noise preamplifiers and detectors revealed by this work. These include the following items: 1. The observation of hole collection at the gate of a FET analogous to ion collection at the grid of a vacuum tube. 2.
Goulding, F.S., Walton, J.T., Pehl, R.H.
openaire +2 more sources

