Results 11 to 20 of about 80,493 (290)
Mechanical Behavior and Failure Analysis of Prosthetic Retaining Screws after Long‐term Use In Vivo. Part 3: Preload and Tensile Fracture Load Testing [PDF]
Purpose: The aim of this study was to determine the preload and tensile fracture load values of prosthetic retaining screws after long‐term use in vivo compared to unused screws (controls).
Al Jabbari, Youssef S. +4 more
core +2 more sources
Despite significant advancements in in vitro cardiac modeling approaches, researchers still lack the capacity to obtain in vitro measurements of a key indicator of cardiac function: contractility, or stroke volume under specific loading conditions ...
Moran Yadid +13 more
doaj +1 more source
What every ICU clinician needs to know about the cardiovascular effects caused by abdominal hypertension [PDF]
The effects of increased intra-abdominal pressure (IAP) on cardiovascular function are well recognized and include a combined negative effect on preload, afterload and contractility.
De Keulenaer, Bart L +2 more
core +1 more source
A pilot study to measure dynamic elasticity of the bladder during urodynamics [PDF]
AIMS: Previous studies using isolated strips of human detrusor muscle identified adjustable preload tension, a novel mechanism that acutely regulates detrusor wall tension. The purpose of this investigation was to develop a method to identify a correlate
Abrams +24 more
core +3 more sources
Myocardial Energy Response to Glyceryl Trinitrate: Physiology Revisited
Objective: Although intravenous nitrates are commonly used in clinical medicine, they have been shown to increase myocardial oxygen consumption and inhibit complex IV of the electron transport chain.
William D. Watson +7 more
doaj +1 more source
Dynamic error characteristics of touch trigger probes used with coordinate measuring machines [PDF]
This paper discusses the dynamic error characteristics of touch trigger probes used with coordinate measuring machines. During the investigation, a number of important parameters have been identified, including measurement speed, probe longitude ...
Butler, C, Johnson, R, Yang, QP
core +1 more source
An experimental study on the rotational accuracy of variable preload spindle-bearing system
The rotational performance of the spindle-bearing system has critical influence upon the geometric shape and surface roughness of the machined parts. The effects of preload and preload method on the rotational performance of the spindle-bearing system is
Gaofeng Hu +6 more
doaj +1 more source
The bearing preload plays an important role on the bearing performance, particularly the important characteristics of the bearing include bearing temperature increases, the bearing fatigue life, and ball skidding.
Yanfang Dong, Zude Zhou, Mingyao Liu
doaj +1 more source
EXOhSPEC collimator mechanical design [PDF]
The Exoplanet High-Resolution Spectrograph (EXOhSPEC) is a high-resolution spectrograph for the characterisation of exoplanets with the Thai National Telescope.
Ahmad +5 more
core +2 more sources
Background and Aims: Doppler waveform analysis of carotid artery has been found to predict fluid responsiveness in patients undergoing elective surgeries.
Apala R Chowdhury +7 more
doaj +1 more source

