Results 31 to 40 of about 7,023,991 (280)

Influence of short implants geometry on primary stability

open access: yesMedicina Oral Patología Oral y Cirugia Bucal, 2018
A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants.Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were ...
González Serrano, José   +5 more
openaire   +4 more sources

Comparative Evaluation of Osseodensification vs Conventional Osteotomy Technique for Dental Implants: A Systematic Review and Meta-analysis [PDF]

open access: yesInternational Journal of Prosthodontics and Restorative Dentistry
Purpose: This systematic review and meta-analysis was conducted to evaluate the efficiency of the osseodensification protocol over the conventional drilling protocol.
Pooja S Poonia, Ina B Patel
doaj   +1 more source

COMPARATIVE STUDY OF PRIMARY STABILITY BETWEEN IMMEDIATE PLACED IMPLANTS AND DELAYED IMMEDIATE PLACED IMPLANTS IN MANDIBULAR SINGLE ROOTED TEETH [PDF]

open access: yesAlexandria Dental Journal, 2018
INTRODUCTION: The timing of implant placement after tooth extraction has been a matter of discussion in dental implant treatment. Primary stability of the implant placed can be measured by the resonance frequency analysis (RFA) which is used to compare ...
Mohab M. Magdy   +2 more
doaj   +1 more source

Investigation of the influence of roughness and dental implant design on primary stability via analysis of insertion torque and implant stability quotient: an in vitro study

open access: yes, 2023
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant.
Brizuela, Aritza   +5 more
core   +2 more sources

Influence of different implant materials on the primary stability of orthodontic mini‐implants

open access: yesThe Kaohsiung Journal of Medical Sciences, 2012
AbstractThis study evaluates the influence of different implant materials on the primary stability of orthodontic mini‐implants by measuring the resonance frequency. Twenty‐five orthodontic mini‐implants with a diameter of 2 mm were used. The first group contained stainless steel mini‐implants with two different lengths (10 and 12 mm). The second group
Chin-Yun Pan   +7 more
openaire   +3 more sources

Osseodensification – A novel approach in implant dentistry

open access: yesThe Journal of Indian Prosthodontic Society, 2018
Primary stability in dental implants is an essential factor for achieving successful osseointegration. Surgical procedure and bone quality are among the most common factors that affect primary stability.
Umesh Y Pai   +3 more
doaj   +1 more source

Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study [PDF]

open access: yesInternational Journal of Environmental Research and Public Health, 2020
The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ).
Mariano Herrero-Climent   +8 more
openaire   +4 more sources

Computational analysis of primary implant stability in trabecular bone [PDF]

open access: yesJournal of Biomechanics, 2015
Secure fixation of fractured osteoporotic bone is a serious clinical challenge mainly because the reduced mechanical competence of low-density bone hampers proper implant fixation. Recent experimental findings have shown strong evidence for a rather complex bone-implant interface contact behavior, with frictional and non-linear mechanical properties ...
Steiner, Juri A.   +2 more
openaire   +3 more sources

Comparison of primary stability in craniofacial implant with V-shape and buttress thread design in goat skull using resonance frequency analysis

open access: yesIndian Journal of Dental Research, 2020
Background and Aims: To find out the primary stability in maxillofacial implant with two different thread designs. Methods: Two group of implants were selected for the study – Group I maxillofacial implant with V-shape thread, and Group II implant with ...
Karthikeyan Ramkumar   +4 more
doaj   +1 more source

Influence of Implant Dimensions and Position on Implant Stability: A Prospective Clinical Study in Maxilla Using Resonance Frequency Analysis

open access: yesApplied Sciences, 2019
Implant stability is relevant for the correct osseointegration and long-term success of dental implant treatments. The aim of this study has been to evaluate the influence of implant dimensions and position on primary and secondary stability of implants ...
Antonio Nappo   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy