Results 1 to 10 of about 57 (51)
Comparison of the Cyclic Fatigue Resistance of ProGlider, PathGlider and One G Path-Finding Instruments [PDF]
Background. The aim of the present study was to compare the cyclic fatigue resistance of novel nickel titanium rotary pathfinding instruments. Methods. Twenty instruments were selected for each file system. A simulated stainless steel root canal, with a
Ahmet Demirhan Uygun +2 more
exaly +2 more sources
Comparative Analysis of Torsional and Cyclic Fatigue Resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in Simulated Curved Canal. [PDF]
ObjectivesThis study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG).Materials and MethodsA total of 15 instruments of each glide path system (n = 15) were used for ...
Rodrigo Ricci Vivan +2 more
exaly +2 more sources
Cyclic Fatigue Resistance of the WaveOne Gold Glider, ProGlider, and the One G Glide Path Instruments in Double-Curvature Canals. [PDF]
ObjectivesThe aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial double-curvature canals.Materials and MethodsThis study included 15 WaveOne Gold Glider ...
Damla Kırıcı, Alper Kuştarcı
exaly +2 more sources
Background: The aim of this study was to comprehensively evaluate the cyclic fatigue strength of ProGlider, Edge Glide Path, and R-Pilot instruments. Methods: Sixty-three instruments were submitted to a multimethod evaluation.
Sofia Arantes-Oliveira +2 more
exaly +3 more sources
Effect of Glide Path Preparation With PathFile and ProGlider on the Cyclic Fatigue Resistance of WaveOne Nickel-Titanium Files. [PDF]
ObjectivesThe aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files.Materials and MethodsForty-four WaveOne Primary files ...
Uğur İnan, Gülşah Uslu
exaly +2 more sources
Objectives It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals.
Koray Yılmaz +2 more
exaly +2 more sources
Aim: The aim of this study was to evaluate the effect of different glide path establishing systems when used along with WaveOne Gold (WOG) single-file reciprocating system and ProTaper Gold (PTG) rotary multifile system on apically extruded debris in ...
Prithwika Swarnakar +4 more
doaj +1 more source
Effects of different glide path techniques on the amount of extruded debris and preparation times during root canal preparation [PDF]
Background.This study purposed to compare the effect of new single glide path files on extruded apical debris and total preparation times during root canal preparation with the WaveOne Gold system. Methods.
Damla Kırıcı +2 more
doaj +1 more source
Introduction: A reproducible glide path provides guidance to fulfil the mechanical objective of cleaning and shaping root canals with minimal procedural errors. Debris expelled during this procedure contributes to inter-appointment flare-up.
V P Anshida +3 more
doaj +1 more source
Introduction: Glide path preparation permits predictable debridement and shaping of radicular space while reducing procedural errors like apical extrusion of debris and microorganisms which can postpone healing. The aim of this study was to comparatively
Priyanka Soni +3 more
doaj +1 more source

