Results 11 to 20 of about 390 (120)

Impact of Different Glidepath Techniques on the Overall Performance of WaveOne Gold in an Artificial S-Shape Canal [PDF]

open access: yesDentistry Journal
Objectives: The article’s aim is to test if rotary or reciprocating glide path influences the overall performance of WaveOne Gold in S-shaped canals. Methods: Sixty endo training blocks with an S-shape curvature were divided into three groups based on ...
Vlad Mircea Lup   +3 more
doaj   +5 more sources

Comparison of mechanical properties and shaping performance of ProGlider and ProTaper ultimate slider [PDF]

open access: yesBMC Oral Health
Background This study aims to compare design, phase transformation behavior, and torsional resistance of the ProGlider (PG) and ProTaper ultimate slider (PUS) and to compare the performance of two files in the glide-path preparation of a double-curved ...
Jeyi Song   +4 more
doaj   +3 more sources

The Hidden Dangers of Counterfeit and Replica‐Like Endodontic Files: A Scoping Review of Current Evidence [PDF]

open access: yesAustralian Dental Journal, Volume 71, Issue 1, Page 5-25, March 2026.
ABSTRACT This scoping review mapped and critically appraised laboratory evidence on counterfeit and replica‐like nickel–titanium endodontic files, evaluating design, metallurgical composition, surface finishing, and mechanical performance to clarify clinical and regulatory implications.
Felipe Immich   +5 more
wiley   +2 more sources

Characterization of the file‐specific heat‐treated ProTaper Ultimate rotary system [PDF]

open access: yesInternational Endodontic Journal, Volume 56, Issue 4, Page 530-542, April 2023., 2023
Abstract Aim To compare design, metallurgy and mechanical performance of the ProTaper (PT) Ultimate system with instruments of similar dimensions from the ProGlider, PT Gold and PT Universal systems. Methodology New PT Ultimate instruments (n = 248) were compared with instruments of similar dimensions from ProGlider (n = 31), PT Gold (n = 155) and PT ...
Jorge N. R. Martins   +7 more
wiley   +2 more sources

Glide-path: comparison between manual instruments, first generation rotary instruments and M-Wire new generation rotary instruments

open access: yesGiornale Italiano di Endodonzia, 2014
Objectives: The aim of this research is to compare the different glide path instruments in order to assess the work time and the number of use for each instrument. Materials and methods: There were used 100 endodontic resin blocks with an S curvature for
Alessandra D’Agostino   +1 more
doaj   +2 more sources

Dynamic torque and screw-in force of four different glide path instruments assessed in simulated single- and double-curved canals: An in vitro study [PDF]

open access: yesJournal of Dental Sciences, 2023
Background/purpose: The glide path instruments are the introductory instruments into the canals; thus, they should be durable enough to withstand torsional stress/screw-in force.
Myint Thu   +7 more
doaj   +2 more sources

Comparison of glide paths created with K-files, PathFiles, and the ProGlider file, and their effects on subsequent WaveOne preparation in curved canals

open access: yesBMC Oral Health, 2018
Background The root canal glide path has been recommended as the foundation for a safer root canal preparation. The aim of this study was to compare glide paths created with K-files, PathFiles, and the ProGlider file, and their effects on subsequent ...
Linxia Zheng   +4 more
doaj   +2 more sources

Comparison of Canal Transportation by Two Rotary Systems, Neoniti vs. Wave One, Both Used with Reciprocal Motion [PDF]

open access: yesFrontiers in Dentistry
Objectives: Preserving the original canal morphology is the ideal goal during root canal preparation. This study aimed to compare canal transportation at various cross-sections using the Neoniti and Wave One Gold rotary systems, both applied with ...
Mohsen Aminsobhani   +2 more
doaj   +2 more sources

Evaluation of shaping ability of different glide path instruments: a micro-computed tomography study [PDF]

open access: yesBMC Oral Health, 2023
Background This study aimed to compare the shaping ability of different instruments, TruNatomy Glider (TRN-G), WaveOne Gold Glider (WOG-G), and ProGlider (Pro-G) using micro-computed tomography (micro-CT).
Merve Yeniçeri Özata   +4 more
doaj   +2 more sources

Estudio comparativo de la conformación generada con las limas ProGlider y WaveOne Gold Glider en conductos curvos simulados Comparative study of the shaping ability generated with ProGlider and WaveOne Gold Glider in simulated curved canals

open access: yesRevista de la Asociación Odontológica Argentina, 2018
Resumen Objetivo: Comparar, en conductos curvos simulados de Endo Training Blocks, la conformación alcanzada por las limas ProGlider y WaveOne Gold Glider. Materiales y métodos: Se utilizaron 20 Endo Training Blocks con conductos curvos.
Florencia Schlie   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy