Results 221 to 230 of about 212,555 (306)

Orthodontic, regenerative, and implant management of a mandibular anterior defect: 5‐year outcome

open access: yesClinical Advances in Periodontics, EarlyView.
Abstract Background Severe alveolar ridge defects in the mandibular anterior region, often associated with congenital tooth absence and subsequent loss of retained primary teeth, present significant challenges for implant rehabilitation. Limited space, horizontal ridge deficiency, and complex site anatomy often require a multidisciplinary approach to ...
Jia Yuan   +3 more
wiley   +1 more source

Comparison Between the Acurate Neo and the Acurate Neo 2 Transcatheter Heart Valve System: Impact of Midframe Under‐Expansion

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius   +9 more
wiley   +1 more source

Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Balloon rupture during transcatheter aortic valve replacement (TAVR) with balloon‐expandable valves is a rare but potentially serious complication that may result in incomplete valve expansion, difficult device retrieval, and vascular injury.
Anne Venkata Ganeshkumar   +5 more
wiley   +1 more source

Mechanisms and Management of Acquired Aseptic Intracardiac Communications After Transcatheter Aortic Valve Implantation: Single‐Center Case Series Insights

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos   +6 more
wiley   +1 more source

Early Experience With Evoque Transcatheter Tricuspid Valve Replacement in Carcinoid Heart Disease

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Tricuspid regurgitation (TR) is nearly universal in carcinoid heart disease (CHD), but surgical replacement carries significant risk, and CHD was excluded from the landmark TRISCEND II trial. We present seven patients with CHD undergoing Evoque transcatheter tricuspid valve replacement (TTVR) at two tertiary centers.
Jackson S. Burton   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy