Results 51 to 60 of about 212,555 (306)
Bio‐Inspired Artificial Ionic Mechanoreceptor
A skin‐inspired artificial mechanoreceptor based on ionic interactions is presented for biomimetic tactile sensing. Pressure‐driven ionic redistribution within microfluidic channels generates a self‐powered electrical signal without external bias. The generated waveform exhibits mechanoreceptor‐like temporal features, including overshoot and undershoot,
Mohammad Akbari +4 more
wiley +1 more source
Load applied on a bone-anchored transfemoral prosthesis: characterisation of a prosthesis : a pilot study [PDF]
The objectives of this study were (A) to record the inner prosthesis loading during activities of daily living (ADL), (B) to present a set of variables comparing loading data, and (C) to provide an example of characterisation of two prostheses.
Branemark, Rickard +3 more
core +1 more source
Prosthesis-Patient Mismatch after Surgical Aortic Valve Replacement: Neither Uncommon nor Harmless
Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) is an issue that has been overlooked (not to say neglected). Cardiac surgeons must bear in mind that this is a real problem that we must tackle. The purpose of this paper is
Alexandre Motta Menezes (4642921) +8 more
core +1 more source
Evaluation of Patient’s Satisfaction with Implant Supported Prosthesis in Rizgary Hospital from 2015- 2019 [PDF]
Objective: This study aims to evaluate patient satisfaction when treated with implant-supported restorations at Dental Implant Unit- Maxillofacial Surgery Department/Rizgary Teaching Hospital in Erbil-Iraq from 2015-2019.
Rekar Ismail +3 more
core +2 more sources
An organic neuromorphic architecture for the classification of human motor behavior is presented and validated. It performs somatic integration by linearly combining the activity from three muscles. An investigation of synaptic weights is presented and discussed in relationship with the classification performance.
Ilenia Sergi +7 more
wiley +1 more source
Generation of fretting wear debris at the stem-cement interface in total hip replacement [PDF]
Fretting wear debris generated at the stem–cement interface has nowadays been considered to play an important role in the overall failure of cemented total hip replacement (THR).
Barrans, Simon +3 more
core +3 more sources
Influence of surface electric charge of Ti implants on osteoblastic interaction: A systematic review
Objective: A critical analysis of the existing literature to answer “What is the influence of electrical charge of titanium alloys in the electrical interaction with osteoblastic cells for osseointegration?”.
Juliana Dias Corpa Tardelli +1 more
doaj +1 more source
A degradable, skin‐conformal bioelectronic patch combines a starch‐dominated nanocomposite conductor with a gelatin substrate to enable sensitive strain sensing, high‐fidelity electrocardiography, electromyography, electrooculography, and machine‐learning‐assisted gesture control.
Ming Dong +10 more
wiley +1 more source
Friction and wear of the Durham finger prosthesis [PDF]
Rheumatoid arthritis of the hand can cause deformities that may severally impair hand function. Surgical procedures including total joint replacement have been developed over the last thirty years to treat patients with metacarpophalangeal deformity. The
Cinzia, Vandelli Dott. Ing.
core
Bioinspired Adaptive Sensors: A Review on Current Developments in Theory and Application
This review comprehensively summarizes the recent progress in the design and fabrication of sensory‐adaptation‐inspired devices and highlights their valuable applications in electronic skin, wearable electronics, and machine vision. The existing challenges and future directions are addressed in aspects such as device performance optimization ...
Guodong Gong +12 more
wiley +1 more source

