Results 111 to 120 of about 745 (237)

Three Ventricular Assist Devices (True TriVAD) as Bridge to Durable Biventricular Support (BiVAD) in LVAD Patient With Severe Aortic Regurgitation

open access: yesArtificial Organs, EarlyView.
An LVAD patient with severe aortic regurgitation (AR) developed right heart failure and multi‐organ dysfunction (MOD). tRVAD support caused LV overload and pulmonary edema. Impella 5.5 implantation successfully unloaded the LV and stabilized the patient, enabling durable RVAD implantation with surgical aortic valve replacement.
Nikolaos Cholevas   +6 more
wiley   +1 more source

Electrical Stimulation of Denervated Muscle: A Narrative Review

open access: yesArtificial Organs, EarlyView.
This review explores existing strategies for stimulating denervated muscle following lower motor neuron injury, including direct electrical stimulation of the muscle and artificial reinnervation to enable more comfortable and efficient indirect functional muscle stimulation.
Linshan Chu   +3 more
wiley   +1 more source

Finger Prosthesis: An Economic and Esthetic Approach. [PDF]

open access: yesCureus, 2023
Kumar A   +4 more
europepmc   +1 more source

Driveline Infections Among Patients Supported With Left Ventricular Assist Devices: A Single Center Sixteen‐Year Longitudinal Profile

open access: yesArtificial Organs, EarlyView.
Our study of 1026 LVAD implants revealed HeartWare had lower driveline infection rates than other LVAD types. In addition, severe diabetes was associated with higher risk, while older age and coronary artery disease were linked to a lower risk of driveline infections.
Anh Nguyen   +6 more
wiley   +1 more source

The influence of denture adhesives on the microhardness, color, and roughness of rigid reliners, before and after thermocycling. [PDF]

open access: yesBiomater Investig Dent
Dos Santos BLM   +5 more
europepmc   +1 more source

Comparison of Biocompatibility and Efficacy of Regional Citrate Anticoagulation and Unfractionated Heparin During Expanded Hemodialysis With a Medium Cut‐Off Membrane—A Randomized Trial

open access: yesArtificial Organs, EarlyView.
In a randomized cross‐over trial, regional citrate anticoagulation provided superior biocompatibility over full‐dose unfractionated heparin during expanded hemodialysis with significantly lower activation of complement, granulocytes, and platelets without affecting dialysis efficiency. ABSTRACT Background Regional citrate anticoagulation (RCA) improves
Marija Malgaj Vrečko   +7 more
wiley   +1 more source

Hemocompatibility and Long‐Term Outcomes in HeartWare Versus HeartMate II Versus HeartMate 3: Multicenter Real‐World Cohort

open access: yesArtificial Organs, EarlyView.
Multicenter real‐world cohort (n = 327) comparing LVADs: HeartMate 3 (HM3), HeartMate II (HMII), and HeartWare (HVAD). HM3 showed superior long‐term survival versus legacy devices, driven by fewer hemocompatibility‐related adverse events, especially pump thrombosis and ischemic stroke, while major bleeding was similar across devices.
Hamza H. H. Ben Nasir   +9 more
wiley   +1 more source