Optimal Determination of Photovoltaic Penetration Level Considering Protection Coordination
IEEE Systems Journal, 2021Photovoltaic (PV) systems have been gaining popularity among distribution network engineers. The integration of these small-scale sources has a variety of benefits for the distribution network.
Sayed Rasoul Kafimousavi Najafabadi +2 more
semanticscholar +1 more source
IEEE Canadian Journal of Electrical and Computer Engineering, 2021
This article is treated with the protection coordination of bidirectional overcurrent relays (OCRs) in distribution power systems to obtain the best performance at a minimum total time dial setting (TDS).
M. Ghanbari, M. Gandomkar, J. Nikoukar
semanticscholar +1 more source
This article is treated with the protection coordination of bidirectional overcurrent relays (OCRs) in distribution power systems to obtain the best performance at a minimum total time dial setting (TDS).
M. Ghanbari, M. Gandomkar, J. Nikoukar
semanticscholar +1 more source
Electric Power Systems Research, 2020
This paper proposes a robust protection coordination scheme of directional overcurrent relays (DOCRs) for multiple network topologies in the presence of on-load tap changers (OLTCs).
Mahamad Nabab Alam +2 more
exaly +2 more sources
This paper proposes a robust protection coordination scheme of directional overcurrent relays (DOCRs) for multiple network topologies in the presence of on-load tap changers (OLTCs).
Mahamad Nabab Alam +2 more
exaly +2 more sources
2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC), 2014
In this paper, common DC-fault detection methods have been reviewed. Effects of two line-to-line and line-to-ground fault types from various fault locations to operation of the DC system are presented. In addition, operation principle, strong and weak points of four main types of protection devices (including fuses, no-fuse circuit breakers, power ...
Duong Minh Bui +5 more
openaire +1 more source
In this paper, common DC-fault detection methods have been reviewed. Effects of two line-to-line and line-to-ground fault types from various fault locations to operation of the DC system are presented. In addition, operation principle, strong and weak points of four main types of protection devices (including fuses, no-fuse circuit breakers, power ...
Duong Minh Bui +5 more
openaire +1 more source
Optimal coordination of protective relays
2013 International Conference on Power, Energy and Control (ICPEC), 2013Protective relays are commonly used as an economical means for protecting power systems. The selection of appropriate settings of these relays under various system conditions plays an important role in timely removal of the faulty section of power system.
D. S. Nair, S. Reshma
openaire +1 more source
Intelligent method for protection coordination
2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings, 2004This paper presents the application of artificial intelligence in protection coordination. It can substantially improve the coordination of protection relay operations. The relay settings and coordination requirements are formulated into a set of constraint equations and an objective function is developed to manage the relay settings by the time ...
C.W. So, K.K. Li
openaire +1 more source
Adaptive Protection Coordination Scheme Using Numerical Directional Overcurrent Relays
IEEE Transactions on Industrial Informatics, 2019Dynamically changing distribution system operating conditions compromises the coordination of the existing protection schemes. This paper proposes an online adaptive protection coordination scheme by utilizing numerical directional overcurrent relays ...
Mahamad Nabab Alam
exaly +2 more sources
Protection Coordination in AC Microgrid via Novel Voltage-Supervised Directional Over-Current Relays
IEEE Transactions on Power DeliveryConventional protection schemes are susceptible to dynamic changes in AC microgrids having diverse Distributed Generators (DGs). These changes, caused by different DG types, significantly alter the fault current levels, leading to conventional ...
A. Soni, A. Mohapatra, Sri Niwas Singh
semanticscholar +1 more source
Smart Grid Conference, 2021
The changes in operation modes of microgrids is one of the most crucial challenges for protection systems. Although communication-based and adaptive protection schemes have various advantages, because of their required infrastructures, much attention has
Amir-Hossein Ataee-Kachoee +2 more
semanticscholar +1 more source
The changes in operation modes of microgrids is one of the most crucial challenges for protection systems. Although communication-based and adaptive protection schemes have various advantages, because of their required infrastructures, much attention has
Amir-Hossein Ataee-Kachoee +2 more
semanticscholar +1 more source
Coordinating overcurrent protection devices
IEEE Computer Applications in Power, 1996Distribution, substation, and plant engineers can benefit from using an overcurrent protection program in commercial, industrial, and utility applications to aid in clearing temporary faults and isolating permanent faults. In the time it normally takes to check one coordination scheme manually, dozens of alternatives can be evaluated using a graphics ...
M. St. John, A. Borgnino
openaire +1 more source