Improving proton dose calculation accuracy by using deep learning
Pencil beam (PB) dose calculation is fast but inaccurate due to the approximations when dealing with inhomogeneities. Monte Carlo (MC) dose calculation is the most accurate method but it is time consuming.
Chao Wu +7 more
doaj +5 more sources
Objective To determine the effect of dose calculation accuracy on inverse linear energy transfer (LET) optimization for intensity‐modulated proton therapy, and to determine whether adding more beams would improve the plan robustness to different dose ...
Mei Chen +11 more
doaj +3 more sources
Background and Purpose: Poor image quality of cone-beam computed tomography (CBCT) images can hinder proton dose calculation to assess the influence of anatomy changes.
Casper Dueholm Vestergaard +6 more
doaj +4 more sources
Parameter Based 4D Dose Calculations for Proton Therapy
Background and purpose Retrospective log file-based analysis provides the actual dose delivered based on the patient's breathing and the daily beam-delivery dynamics. To predict the motion sensitivity of the treatment plan on a patient-specific basis before treatment start a prospective tool is required.
Markus Stock +2 more
exaly +4 more sources
Calculation of Clinical Dose Distributions in Proton Therapy From Microdosimetry [PDF]
PurposeTo introduce a new algorithm—MicroCalc—for dose calculation by modeling microdosimetric energy depositions and the spectral fluence at each point of a particle beam. Proton beams are considered as a particular case of the general methodology.
Alejandro Carabe-Fernandez +2 more
exaly +5 more sources
Fast pencil beam dose calculation for proton therapy using a double-Gaussian beam model
The highly conformal dose distributions produced by scanned proton pencil beams are more sensitive to motion and anatomical changes than those produced by conventional radiotherapy.
Joakim eda Silva +3 more
doaj +3 more sources
Background and purpose: Proton therapy requires dose monitoring, often performed based on repeated computed tomography (reCT) scans. However, reCT scans may not accurately reflect the internal anatomy and patient positioning during treatment.
Casper Dueholm Vestergaard +7 more
doaj +3 more sources
Towards implementation of independent calculation-based dose verification in proton therapy.
BackgroundProton therapy offers precision in targeting tumors while minimizing damage to surrounding healthy tissues. Independent dose calculation is a secondary dose validation tool for patient-specific quality assurance (PSQA) using Monte Carlo ...
Nichakan Chatchumnan +4 more
doaj +4 more sources
Background and purpose: Proton therapy currently relies on computed tomography (CT) imaging despite magnetic resonance imaging’s (MRI) superior soft-tissue contrast.
Muheng Li +5 more
doaj +3 more sources
Quantification of Proton Dose Calculation Accuracy in the Lung [PDF]
To quantify the accuracy of a clinical proton treatment planning system (TPS) as well as Monte Carlo (MC)-based dose calculation through measurements and to assess the clinical impact in a cohort of patients with tumors located in the lung.A lung phantom and ion chamber array were used to measure the dose to a plane through a tumor embedded in the lung,
Grassberger, Clemens +5 more
openaire +4 more sources