Dedicated simulations show that the application of time-domain ptychography to angular photo-electron streaking data allows shot-to-shot reconstruction of individual X-ray free electron laser pulses.
Tobias Schweizer +5 more
doaj +3 more sources
Single-pixel ptychography [PDF]
Ptychography is a predominant non-interferometric technique to image large complex fields but with quite a narrow working spectrum, because diffraction measurements require dense array detection with an ultra-high dynamic range. Here we report a single-pixel ptychography technique that realizes non-interferometric and non-scanning complex-field imaging
Meng Li +8 more
openaire +2 more sources
Acousto-optic imaging (AOI) enables optical-contrast imaging deep inside scattering samples via localized ultrasound-modulation of scattered light. While AOI allows optical investigations at depths, its imaging resolution is inherently limited by the ultrasound wavelength, prohibiting microscopic investigations. Here, we propose a computational imaging
Rosenfeld, Moriya +5 more
openaire +2 more sources
We present a ptychography method to fuse data from two image sensors capturing different parts of the diffraction patterns and thereby extending the numerical aperture.
Kira Maathuis +2 more
openaire +3 more sources
Direct observation of Cu in Cu-chabazite (CHA) zeolite has been achieved by electron ptychography using the Wigner distribution deconvolution. The imaging properties of ptychographically reconstructed images were evaluated by comparing the intensities of
Kazutaka Mitsuishi +6 more
doaj +1 more source
Spectro-ptychography offers improved spatial resolution and additional phase spectral information relative to that provided by scanning transmission X-ray microscopes.
Jaianth Vijayakumar +8 more
doaj +1 more source
AbstractWe report an experimental ptychography measurement performed in fly-scan mode. With a visible-light laser source, we demonstrate a 5-fold reduction of data acquisition time. By including multiple mutually incoherent modes into the incident illumination, high quality images were successfully reconstructed from blurry diffraction patterns.
Huang, X +7 more
openaire +4 more sources
Enhancing Dose Efficiency of Optimum Bright-Field Scanning Transmission Electron Microscopy Using a Phase-Shifted Electron Probe. [PDF]
ABSTRACT Observing beam‐sensitive materials using scanning transmission electron microscopy (STEM) at low electron dose conditions is challenging due to the low signal‐to‐noise ratio (SNR) of images. In this study, we aimed to improve the SNR of optimum bright‐field (OBF) STEM by introducing phase shifts to the incident electron probe using lens ...
Nogami M, Seki T, Ooe K, Shibata N.
europepmc +2 more sources
Reflective Fourier ptychography [PDF]
The Fourier ptychography technique in reflection mode has great potential applications in tissue imaging and optical inspection, but the current configuration either has a limitation on cut-off frequency or is not practical. By placing the imaging aperture stop outside the illumination path, the illumination numerical aperture (NA) can be greater than ...
Shaun, Pacheco +2 more
openaire +2 more sources