Results 231 to 240 of about 73,555 (300)
A computational model for retinal haemodynamics under gravitational and postural variations
Abstract figure legend The haemodynamic impact of gravitational and postural changes on the retina, and its relevance to spaceflight associated neuro‐ocular syndrome (SANS), remains incompletely characterized. This study assesses retinal haemodynamics from upright to head‐down tilt using a lumped‐parameter model that dynamically couples intraocular ...
Michele Nigro +2 more
wiley +1 more source
Abstract figure legend After high‐intensity interval training (HIIT), endurance athletes demonstrated a reduction in pain perception, alongside decreased oxyhaemoglobin concentrations in the prefrontal, sensorimotor and posterior parietal cortices.
Maria Geisler +6 more
wiley +1 more source
ABSTRACT Purpose To develop accelerated 3D phase contrast (PC) MRI using jointly learned wave encoding and reconstruction. Methods Pseudo‐fully sampled neurovascular 4D flow data (N = 40) and a simulation framework were used to learn phase encoding locations, wave readout parameters, and model‐based reconstruction network (MoDL) for a rapid 3D PC scan (
Chenwei Tang +7 more
wiley +1 more source
Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses
ABSTRACT Purpose The goal of this article is to introduce a technique to measure the velocity distribution of water inside each voxel of an MR image. The method is based on the use of motion sensitizing gradients with changing first moment to encode velocity. As such, it is completely non‐invasive and requires no contrast injections.
Luis Hernandez‐Garcia +2 more
wiley +1 more source
Pancreatic exocrine microcirculation exhibits sexual dimorphism arising from steroid–genetic interactions. Laser Doppler flowmetry combined with wavelet analysis identifies a male passive coupling phenotype aligned with systemic pressure and a female active vasomotion phenotype driven by ERβ‐mediated, NO‐dependent oscillations.
Yuan Li +8 more
wiley +1 more source
Abstract Secondary aortoduodenal fistula (sADF) is a rare but life‐threatening complication after aortic graft surgery. Diagnosis is often challenging, particularly when contrast‐enhanced computed tomography (CT) and endoscopy results are inconclusive. We report a case in which diagnosis was challenging due to contrast media allergy and non‐diagnostic ...
Jun Kubota +6 more
wiley +1 more source
Motion Mitigation Techniques for Abdominal and Cardiac MR Imaging
ABSTRACT MRI of the heart and abdominal organs provides unparalleled soft tissue contrast and quantitative biomarkers, yet remains highly susceptible to physiological motion. Contractions of the myocardium, respiratory excursions, peristalsis, vascular pulsatility, and unpredictable bulk patient movement generate artifacts that impair image quality ...
Eric M. Schrauben +3 more
wiley +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Transactions of the Society of Rheology, 1973
In this paper pulsatile blood flow through rigid circular tubes due to a sinusoidally varying pressure gradient is analyzed using a microcontinuum model of blood. A new boundary condition, which is in accord with experimental observations on blood flow in small rigid tubes, has been proposed to describe red blood cell rotations at a solid boundary ...
Turk, Martin A. +2 more
openaire +2 more sources
In this paper pulsatile blood flow through rigid circular tubes due to a sinusoidally varying pressure gradient is analyzed using a microcontinuum model of blood. A new boundary condition, which is in accord with experimental observations on blood flow in small rigid tubes, has been proposed to describe red blood cell rotations at a solid boundary ...
Turk, Martin A. +2 more
openaire +2 more sources
Pulsatile Flow in Hemodialyzers
Journal of Dialysis, 1978The present work is concerned with the calculation of NaCl transfer in flowing solutions and its dependence upon flow characteristics at hemodialyzers. A theoretical analysis of the solute transfer in a hemodialyzer is presented. Experiments were carried out with a continuous flow flat-plate dialyzer.
A R, Ozdural, E, Piskin
openaire +2 more sources

