Results 71 to 80 of about 922,025 (371)

Pleth variability index versus pulse pressure variation for intraoperative goal-directed fluid therapy in patients undergoing low-to-moderate risk abdominal surgery: a randomized controlled trial

open access: yesBMC Anesthesiology, 2019
BackgroundGoal-directed fluid therapy (GDFT) based on dynamic indicators of fluid responsiveness has been shown to decrease postoperative complications and hospital length of stay (LOS) in patients undergoing major abdominal surgery.
Sean Coeckelenbergh   +6 more
semanticscholar   +1 more source

Different W cluster deposition regimes in pulsed laser ablation observed by in situ Scanning Tunneling Microscopy [PDF]

open access: yesSurface Science 601, 1892-1897 (2007), 2007
We report on how different cluster deposition regimes can be obtained and observed by in situ Scanning Tunneling Microscopy (STM) by exploiting deposition parameters in a pulsed laser deposition (PLD) process. Tungsten clusters were produced by nanosecond Pulsed Laser Ablation in Ar atmosphere at different pressures and deposited on Au(111) and HOPG ...
arxiv   +1 more source

Laser Absorption Measurements of Electron Density in Nanosecond-ScaleAtmospheric Pressure Pulsed Plasmas [PDF]

open access: yes, 2021
We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electron excitation, with the absorption coefficient modeled and evaluated using estimates of the time ...
arxiv   +1 more source

Abnormal wave reflections and left ventricular hypertrophy late after coarctation of the aorta repair [PDF]

open access: yes, 2017
Patients with repaired coarctation of the aorta are thought to have increased afterload due to abnormalities in vessel structure and function. We have developed a novel cardiovascular magnetic resonance protocol that allows assessment of central ...
Khushnood, Abbas   +7 more
core   +2 more sources

Evaluation of systolic pressure variation and pulse pressure variation in an experimental model of acute normovolemic hemodilution [PDF]

open access: yesCritical Care, 2008
Dynamic indicators derived from the arterial pressure waveform analysis as systolic pressure variation (SPV) and pulse pressure variation (PPV) have been shown to be a useful tool to optimize tissue perfusion in clinical and experimental studies. These indicators, however, have not been adequately explored in situations of acute variation of blood ...
JO Auler   +3 more
openaire   +2 more sources

Reversal of aging-induced increases in aortic stiffness by targeting cytoskeletal protein-protein interfaces [PDF]

open access: yes, 2018
BACKGROUND: The proximal aorta normally functions as a critical shock absorber that protects small downstream vessels from damage by pressure and flow pulsatility generated by the heart during systole.
Chiu, Joanna   +10 more
core   +4 more sources

The effect of positive end-expiratory pressure on pulse pressure variation

open access: yesSouthern African Journal of Anaesthesia and Analgesia, 2012
Objectives: To determine the effect of different levels of positive end-expiratory pressure (PEEP) on pulse pressure variation (PPV).Design: An observational study. Setting: Operating theatres of a tertiary training hospital.Subjects: Ventilated patients who required intra-arterial blood pressure monitoring.Outcome measures: PPV during different levels
Smith, Francois Jacobus   +3 more
openaire   +3 more sources

Injectable Bubbles for Physiological Pressure Measurement [PDF]

open access: yesarXiv, 2022
Microbubbles - used as contrast agents in ultrasound imaging - are important tools in biomedical research, having been used together with ultrasound to develop significant diagnostic and therapeutic techniques. It has been suggested that the dynamic behaviour of microbubbles is dependent on the surrounding fluid's ambient (hydrostatic) pressure, and ...
arxiv  

Experimental study on pulse characteristics of negative corona discharge in SF6/N2 gas mixtures under DC voltages

open access: yesAIP Advances, 2020
Corona discharge, an inevitable phenomenon, may lead to insulation degradation, threatening the safe and reliable operation of gas-insulated power equipment. The pulse stage is a complex but usual discharge process in corona discharge.
Yanliang He   +5 more
doaj   +1 more source

Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: a clinical study [PDF]

open access: yes, 2010
Pulse-pressure variation (PPV) due to increased right ventricular afterload and dysfunction may misleadingly suggest volume responsiveness. We aimed to assess prediction of volume responsiveness with PPV in patients with increased pulmonary artery ...
Baenziger, Bertram   +9 more
core   +2 more sources

Home - About - Disclaimer - Privacy