NEMESIS-PFA: Investigating Collateral Tissue Injury Associated with Pulsed Field Ablation.
JACC Clinical ElectrophysiologyBACKGROUND Early evidence showed reduced complications with pulsed field ablation (PFA), but non-target tissue collateral damage created by electroporation effects is poorly understood and may significantly differ between systems.
D. Lakkireddy +20 more
semanticscholar +1 more source
Europace
Aims Pulsed field ablation (PFA) is a growing ablation modality for pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients. This study assesses the 6-month safety and effectiveness of a novel balloon-in-basket, mapping-integrated PFA system,
R. Tilz +17 more
semanticscholar +1 more source
Aims Pulsed field ablation (PFA) is a growing ablation modality for pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients. This study assesses the 6-month safety and effectiveness of a novel balloon-in-basket, mapping-integrated PFA system,
R. Tilz +17 more
semanticscholar +1 more source
Hemolysis After Pulsed-Field Ablation of Atrial Fibrillation.
Heart RhythmPulsed-field ablation (PFA) offers notable advantages in atrial fibrillation (AF) ablation by selectively targeting cardiomyocytes via an irreversible electroporation mechanism, thereby minimizing damage to surrounding tissues.
Yuankai Xu +6 more
semanticscholar +1 more source
Europace
Aims Studies have shown correlations between early recurrence (ER) and late recurrence (LR) of atrial arrhythmia after ablation with thermal technologies. This admIRE trial (NCT05293639) subanalysis aims to analyse ER vs.
L. di Biase +13 more
semanticscholar +1 more source
Aims Studies have shown correlations between early recurrence (ER) and late recurrence (LR) of atrial arrhythmia after ablation with thermal technologies. This admIRE trial (NCT05293639) subanalysis aims to analyse ER vs.
L. di Biase +13 more
semanticscholar +1 more source
Comparison of Hemolysis with Different Pulsed Field Ablation Systems.
Heart RhythmBACKGROUND Hemolysis is one of the unique complications of pulsed field ablation (PFA), but the differences in hemolysis between the different PFA systems are not well understood.
I. Kawamura +14 more
semanticscholar +1 more source
Circulation: Arrhythmia and Electrophysiology
BACKGROUND The safety and efficacy of pulsed field ablation for pulmonary vein and posterior wall isolation in atrial fibrillation ablation are well established; however, evidence regarding its use in extra-pulmonary vein areas remains limited.
V. L. La Fazia +13 more
semanticscholar +1 more source
BACKGROUND The safety and efficacy of pulsed field ablation for pulmonary vein and posterior wall isolation in atrial fibrillation ablation are well established; however, evidence regarding its use in extra-pulmonary vein areas remains limited.
V. L. La Fazia +13 more
semanticscholar +1 more source
Circulation
BACKGROUND: Evidence from clinical trials of early pulsed field ablation (PFA) systems in treating atrial fibrillation has demonstrated their promising potential to reduce complications associated with conventional thermal modalities while maintaining ...
V. Reddy +16 more
semanticscholar +1 more source
BACKGROUND: Evidence from clinical trials of early pulsed field ablation (PFA) systems in treating atrial fibrillation has demonstrated their promising potential to reduce complications associated with conventional thermal modalities while maintaining ...
V. Reddy +16 more
semanticscholar +1 more source
Heart Rhythm
BACKGROUND Catheter-tissue contact is critical in creating durable lesions during pulsed-field ablation (PFA) of atrial fibrillation (AF). OBJECTIVE We aimed to compare the reconnection rate of previously ablated targets utilizing PFA with vs without ...
S. Mohanty +19 more
semanticscholar +1 more source
BACKGROUND Catheter-tissue contact is critical in creating durable lesions during pulsed-field ablation (PFA) of atrial fibrillation (AF). OBJECTIVE We aimed to compare the reconnection rate of previously ablated targets utilizing PFA with vs without ...
S. Mohanty +19 more
semanticscholar +1 more source
Heart Rhythm
BACKGROUND Pulsed field ablation (PFA) for paroxysmal atrial fibrillation (AF) has been gaining worldwide acceptance due to its efficacy and safety. A variable loop circular catheter (VLCC, VARIPULSE, Biosense Webster, Inc.) for PFA, recently launched in
Yuji Saito +9 more
semanticscholar +1 more source
BACKGROUND Pulsed field ablation (PFA) for paroxysmal atrial fibrillation (AF) has been gaining worldwide acceptance due to its efficacy and safety. A variable loop circular catheter (VLCC, VARIPULSE, Biosense Webster, Inc.) for PFA, recently launched in
Yuji Saito +9 more
semanticscholar +1 more source
Heart Rhythm
BACKGROUND Increasing utilization of Pulsed Field Ablation (PFA) to treat atrial fibrillation (AF) has led to concerns related to tissue contact, hemolysis, and electroanatomic mapping integration.
Monica Y. Lo +19 more
semanticscholar +1 more source
BACKGROUND Increasing utilization of Pulsed Field Ablation (PFA) to treat atrial fibrillation (AF) has led to concerns related to tissue contact, hemolysis, and electroanatomic mapping integration.
Monica Y. Lo +19 more
semanticscholar +1 more source