Results 121 to 130 of about 2,322 (247)
ABSTRACT Purpose To develop a phase‐corrected time‐interleaved multi‐echo gradient echo Cartesian acquisition with spiral profile ordering (TIMGRECASPR) for abdominal large‐FOV proton density fat fraction (PDFF) mapping at 3 T, demonstrating its sampling flexibility and inherent self‐gating capabilities at high isotropic resolutions.
Philipp Braun +7 more
wiley +1 more source
ABSTRACT Purpose To integrate MR‐based servo navigation in MPRAGE and 3D‐TSE sequences and demonstrate its potential for prospective head motion correction in structural imaging. Methods Repeated modules of servo navigators were inserted before each preparation pulse of MPRAGE and 3D‐TSE sequences (before‐prep) for rapid convergence of motion parameter
Matthias Serger +7 more
wiley +1 more source
Study on the effect of pulsed eddy current lift-off characteristics for feeding metallic foreign objects detection in coal mine crushers. [PDF]
Meng B, Zhuang Z, Ma J, Zhao S.
europepmc +1 more source
Imaging of Subsurface Corrosion Using Gradient-Field Pulsed Eddy Current Probes with Uniform Field Excitation. [PDF]
Li Y +4 more
europepmc +1 more source
ABSTRACT Introduction Despite the relevance of neuromuscular electrical stimulation (NMES) dosimetry, it is unclear whether increasing the self‐reported tolerated amplitude enhances acute neuromuscular responses. Objective To investigate the acute effects of varying NMES amplitude and type of induced contraction on quadriceps isometric torque (IT) and ...
Jhonatan Zini dos Anjos +5 more
wiley +1 more source
A Gradient-Field Pulsed Eddy Current Probe for Evaluation of Hidden Material Degradation in Conductive Structures Based on Lift-Off Invariance. [PDF]
Li Y, Jing H, Zainal Abidin IM, Yan B.
europepmc +1 more source
Thermal black improves polyurethane foam structure and stability. It helps the foam rise smoothly while promoting the formation of smaller, more uniform cells. The foam keeps its strength and insulation performance while reducing shrinkage. Its clean production and easy processing make it a sustainable, cost‐effective option for high‐performance ...
Mihaela Mihai +3 more
wiley +1 more source
ABSTRACT This preregistered study investigated whether induced electric fields alone could predict human perception thresholds in magnetic stimulation. Using a figure‐of‐eight magnetic coil placed on the forearm, perception thresholds were collected from 24 healthy participants using the method of adjustment in 12 stimulation conditions. Subject‐fitted,
Otto Kangasmaa, Ilkka Laakso
wiley +1 more source
Principles of Pulsed Eddy Current Nondestructive Testing [PDF]
openaire +1 more source

