Results 261 to 270 of about 967,429 (300)
Some of the next articles are maybe not open access.
Annual Meeting Optical Society of America, 1987
The degree of squeezing generated by parametric downconversion or four-wave mixing can be limited by the ratio of the nonlinear coupling to the linear losses in many practical systems. This ratio can be enhanced by increasing the pump power used for the nonlinear coupling in many solid nonlinear systems where the linear losses are not directly related ...
, Slusher +4 more
openaire +2 more sources
The degree of squeezing generated by parametric downconversion or four-wave mixing can be limited by the ratio of the nonlinear coupling to the linear losses in many practical systems. This ratio can be enhanced by increasing the pump power used for the nonlinear coupling in many solid nonlinear systems where the linear losses are not directly related ...
, Slusher +4 more
openaire +2 more sources
The Annals of Thoracic Surgery, 1978
Pulsatile and nonpulsatile blood flow have been intensely studied for cardiopulmonary bypass (CPB), isolated organ perfusion, and myocardial preservation. Although early studies differed, later ones have shown the benefits of pulsatile flow. Kidney function, lymph flow, and oxygen consumption are increased during pulsatile perfusion. Also, nonpulsatile
openaire +2 more sources
Pulsatile and nonpulsatile blood flow have been intensely studied for cardiopulmonary bypass (CPB), isolated organ perfusion, and myocardial preservation. Although early studies differed, later ones have shown the benefits of pulsatile flow. Kidney function, lymph flow, and oxygen consumption are increased during pulsatile perfusion. Also, nonpulsatile
openaire +2 more sources
2011
In addition to lasers, intense pulsed light (IPL) sources are widely used in medicine to treat various indications, such as vascular lesions, irregular pigmentation and hypertrichosis. In contrast to lasers, IPL systems are broadband flash lamps that emit polychromatic incoherent light ranging from visible to infrared (500-1,300 nm).
Schoenewolf, N L +2 more
openaire +2 more sources
In addition to lasers, intense pulsed light (IPL) sources are widely used in medicine to treat various indications, such as vascular lesions, irregular pigmentation and hypertrichosis. In contrast to lasers, IPL systems are broadband flash lamps that emit polychromatic incoherent light ranging from visible to infrared (500-1,300 nm).
Schoenewolf, N L +2 more
openaire +2 more sources
Journal of Steroid Biochemistry, 1983
If micro-sampling techniques are used in conjunction with a highly sensitive radioimmunoassay procedure, it is possible to obtain repeated rapid measurements of plasma corticosterone concentrations from unanesthetized rats. Such a procedure reveals the existence of rapid corticosterone pulses with a duration of less than 60 s and amplitudes as great as
openaire +2 more sources
If micro-sampling techniques are used in conjunction with a highly sensitive radioimmunoassay procedure, it is possible to obtain repeated rapid measurements of plasma corticosterone concentrations from unanesthetized rats. Such a procedure reveals the existence of rapid corticosterone pulses with a duration of less than 60 s and amplitudes as great as
openaire +2 more sources
Pulse distortions in tilted pulse schemes for ultrashort pulses
Optics Communications, 1986Abstract Analytical expressions are found for the propagation of the amplitude of tilted ultrashort pulses. The distortions arising are the pulse broadening, tilt angle decrease, chirp, frequency shift and spatial profile variation. Expressions for these quantities are found and it is shown that the mechanisms responsible for the distortions are the ...
openaire +1 more source
Pulse Cycles, Pulse Sequences, and Tissue Contrast
1989In order to create an image in space, steps 2 and 3 of MRR must be repeated multiple times. That is, the RF pulse must be applied over and over with relaxation and signal measurement occurring after each application of the pulse. The number of such repetitions is usually on the order of 128 or 256 (or some other multiple of 64).
openaire +1 more source
Molecular Chirality and Its Monitoring by Ultrafast X-ray Pulses
Chemical Reviews, 2022Jérémy R Rouxel, Shaul Mukamel
exaly
Writing magnetic memory with ultrashort light pulses
Nature Reviews Materials, 2019Alexey Kimel, Mo Li
exaly

