PVC membrane and All-Solid-Sate Sensor for the Potentiometric Analysis of Trimipramine
Two symmetrical and asymmetrical potentiometric membrane electrodes were developed and evaluated for the analysis Trimipramine (TMP). The symmetrical electrode was a poly(vinyl chloride) (PVC) membrane electrode (PME), a similar membrane of which was ...
Maryam Sharifi-Sistani +3 more
doaj +1 more source
The Study on a PVC Membrane Electrode for Gemfibrozil.
In this paper, a poly(vinyl chloride) (PVC) membrane electrode is prepared for gemfibrozil, 2, 2-dimethyl-5-(2,5-xylyloxy) valeric acid, based on its ion pair complexes with hexadecyltrioctyl ammonium iodide (HTOA). The membrane composition of the electrode was optimized by using the sequential level elimination method for orthogonal experimental ...
Xu, Fen +5 more
openaire +3 more sources
PVC Membrane Sensor and Wire Coated Electrode for Determination of Flurazepam
Flurazepam is a benzodiazepine derivative which possesses anxiolytic, anticonvulsant, sedative and skeletal muscle relaxant properties. This research introduces two kinds of PVC membrane sensor (symmetric and asymmetric) for determination of flurazepam ...
Parviz Norouzi +5 more
doaj +1 more source
Potentiometric PVC membrane Sensor for the Determination of Terbinafine
In this work, potentiometry was used for the determination of Terbinafine which is one of the antifungal drugs. The indicator electrode used in the potentiometric method was a kind of PVC membrane sensor.
Farnoush Faridbod +2 more
doaj +1 more source
The use of different ionophores for the determination of Zn2+ ions
In this study, poly(vinly chloride) (PVC) membrane ion–selective electrodes for the determination of zinc(II) ions were prepared using potassium hydrotris(N-tert-butyl-2-thioimidazolyl)borate (L1), 1-[Bis(dimethylamino)methylen]-5-chlorobenzotriazolium-3-
Ömer Isildak +2 more
doaj +1 more source
Glycosylated Metalloporphyrins as Neutral Carriers for PVC Membrane Electrodes
In this paper, the synthesis of a novel ionophore, chloro[5,10,15,20-tetrakis[2-(2,3,4,6-tetraacetyl-beta-D-glucopyranosyl)-1-O-phenyl]porphinato]manganese (MnT(o-glu)PPCl), and its application as a neutral carrier for a PVC membrane electrode are described. The MnT(o-glu)PPCl-based PVC membrane electrode shows a potentiometric responses to SCN- over a
Zhi-Zhang, Li +4 more
openaire +3 more sources
Potentiometric Determination of Betahistine in Pharmaceutical Formulations by Drug Selective Sensors
Betahistine is histamine like drug that acts as both a partial histamine H1 receptor agonist and as a histamine H3 receptor antagonist. This research introduces design and construction of a PVC membrane sensor and nano-composite carbon paste electrode ...
Mohammad Reza Ganjali +3 more
doaj +1 more source
Cetrimide Potentiometric PVC membrane Sensor
In the present work, two types of potentiometric electrodes were constructed for determination of cetrimide. The sensors demonstrated advanced performances with a fast response time, a lower detection limit of 4.0×10-6 M and potential responses across ...
Farnoush Faridbod +4 more
doaj +1 more source
Developing a potentiometric sunset yellow selective electrode and its applications
We developed a potentiometric ion-selective electrode (ISE) for detecting the food dye sunset yellow (SY). Sunset yellow-Methyltrioctylammonium chloride ion pairs were synthesized.
Gülşah Saydan Kanberoğlu +1 more
doaj +1 more source
Fluoxetine Determination by PVC membrane and Nano-Composite Carbon Paste Electrodes
Fluoxetine is one of the most prescribed antidepressant drug. Two kinds of potentiometric sensor were made for determination of fluoxetine. Both sensors respond based on ion-exchange mechanism.
Mohammad Reza Ganjali +5 more
doaj +1 more source

