Results 61 to 70 of about 3,456 (182)
Connexin43 Deficiency Leads to Ventricular Arrhythmias by Reprogramming Proline Metabolism
The study demonstrated that connexin43 (Cx43) knockout caused arrhythmic phenotype and decreased proline content in vitro and in vivo. Mechanistically, Cx43 interacts with the amino acid transporter SNAT2 (sodium‐dependent neutral amino acid transporter), and its deficiency disrupts proline transport and metabolism.
Hangying Ying +8 more
wiley +1 more source
Experimental and theoretical investigation of acetamiprid adsorption on nano carbons and novel PVC membrane electrode for acetamiprid measurement. [PDF]
Razavi R +3 more
europepmc +1 more source
Potentiometric Sensor for Determination of Clomiphene
In this work, construction and analytical application of a new potentiometric PVC membrane sensor for the determination of Clomiphene are studied. The sensor respond based on ion-exchange mechanism between the organic layer of the membrane and aqueous ...
Farnoush Faridbod +3 more
doaj +1 more source
PVC-Based Cerium Phosphate Membrane Exhibiting Selectivity for Molybdate Anions [PDF]
A PVC-based membrane containing cerium phosphate was developed. Unlike the cerium phosphate itself that acts as a cation exchanger, the membrane exhibited anion-exchange properties.
Hassan Khodakarami +1 more
doaj
Hydrogen ion selective membranes formulated with 3140 RTV silicone rubber (SR) in PVC were studied to extend the life time of solid state ion sensors through improved membrane adhesion.
Yoon-Bo Shim +3 more
doaj +1 more source
One of the selective serotonin reuptake inhibitors (SSRIs) is Paroxetine which is used as an antidepressant compound. A PVC membrane electrode (PME), as a symmetric potentiometric sensor and all solid state polymeric membrane electrode (ASS-PME) as an ...
Farnoush Faridbod +2 more
doaj +1 more source
Clenbuterol Determination in Pharmaceutical Formulation by Potentiometric Membrane Sensor
Clenbuterol is a selective β2-adrenoceptor agonist which has been known as a thermogenic drug. This work introduces design and construction of a PVC membrane sensor for fast and simple determination of Clenbuterol in pharmaceutical formulation.
Farnoush Faridbod, Masoomeh Dorrani
doaj +1 more source
Development of Ammonium-Selective Electrode Based on PVC/MB28 Membrane
In this study, the ISE-NH4 + sensor based on hybrid membrane of the poly (vinyl chloride)/methyl methacrylate-butyl acrylate 2:8 co-polymer (PVC/MB28) has been successfully developed, where the ratio between PVC: MB28 is 9:1. Meanwhile, the plasticized material used is dioctyl sebacate (DOS) of 66.34 wt.
Sagir Alva +4 more
openaire +1 more source
Sn (II) selective 2-Amino-1,4-Naphthoquinone Derived poly(vinyl chloride) Membrane Sensors
The two quinone derivatives, 2-( N-alkenyl) amino-1,4-naphthoquinone (M1) and 2-(N-1-butenyl)amino-1,4-naphthoquinone (M2), have been synthesized and explored as ionophores for preparing PVC-based membrane sensors selective to stannous ion.
Abdullah J. Hamdan
doaj +1 more source
Sensor for Silver(I) Ion Based on Schiff-base-p-tertbutylcalix[4]arene
The preparation of polymer membrane selective to silver ion and its application to ion-selective electrode is reported here. PVC membrane contain silver-selective calix[4]arene derivative as ionophore. The membrane electrode is highly selective to silver
M. Kumar +3 more
doaj +1 more source

