Results 51 to 60 of about 739,334 (261)

Value of MRI Outcomes for Preventive and Early‐Stage Trials in Spinocerebellar Ataxias 1 and 3

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective To examine the value of MRI outcomes as endpoints for preventive and early‐stage trials of two polyglutamine spinocerebellar ataxias (SCAs). Methods A cohort of 100 participants (23 SCA1, 63 SCA3, median Scale for the Assessment and Rating of Ataxia (SARA) score = 5, 42% preataxic, and 14 gene‐negative controls) was scanned at 3T up ...
Thiago J. R. Rezende   +26 more
wiley   +1 more source

In Quantum Computing Speedup Illusory?: The False Coin of "Counting Function Evaluations"

open access: yes, 2020
By using a new way to encode Boolean functions in a reversible gate, an algorithm is developed in quantum computing over Z_2, symbolized QC/2, (as opposed to QC over C) that needs only one function evaluation to solve the Grover Database Search Problem ...
Ellerman, David
core  

Scalable quantum computing with Josephson charge qubits

open access: yes, 2003
A goal of quantum information technology is to control the quantum state of a system, including its preparation, manipulation, and measurement. However, scalability to many qubits and controlled connectivity between any selected qubits are two of the ...
D. Deutsch   +4 more
core   +1 more source

Complementarity of Long‐Reads and Optical Mapping in Parkinson's Disease for Structural Variants

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Long‐read sequencing and optical genome mapping technologies have the ability to detect large and complex structural variants. This has led to the discovery of novel pathogenic variants in neurodegenerative movement disorders. Thus, we aimed to systematically compare the SV detection capabilities of OGM and ONT in Parkinson's disease.
André Fienemann   +17 more
wiley   +1 more source

Development of an automated quality control and assay performance management system for biochemical genetics laboratory

open access: yesMolecular Genetics and Metabolism Reports
Objectives: Quality control (QC) in clinical laboratory is critical to ensuring quality and accuracy of patient results. However, QC monitoring is complicated in the multi-analyte, multi-instrument assays common to biochemical genetics laboratories ...
P. Tanpaiboon   +4 more
doaj   +1 more source

A Systematic Comparison of Alpha‐Synuclein Seed Amplification Assays for Increasing Reproducibility

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Seed amplification assays (SAAs) enable ultrasensitive detection of misfolded α‐synuclein across biofluids and tissues. Yet, heterogeneity in protocols limits cross‐study comparability and clinical translation. Here, we review α‐synuclein SAA methods and their performance across various biological matrices.
Manuela Amaral‐do‐Nascimento   +3 more
wiley   +1 more source

The Development of Quality Control Genotyping Approaches: A Case Study Using Elite Maize Lines. [PDF]

open access: yesPLoS ONE, 2016
Quality control (QC) of germplasm identity and purity is a critical component of breeding and conservation activities. SNP genotyping technologies and increased availability of markers provide the opportunity to employ genotyping as a low-cost and robust
Jiafa Chen   +7 more
doaj   +1 more source

Ofatumumab in Myelin Oligodendrocyte Glycoprotein Antibody–Associated Disease: A Comparison With Rituximab

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective To evaluate the efficacy and safety of ofatumumab in patients with myelin oligodendrocyte glycoprotein antibody–associated disease (MOGAD), and compare it with rituximab. Methods We conducted a single–center, observational study including 22 MOGAD patients treated with ofatumumab and 21 treated with rituximab.
Yuxin Fan   +5 more
wiley   +1 more source

The OSCAR-IB consensus criteria for retinal OCT quality assessment.

open access: yesPLoS ONE, 2012
BackgroundRetinal optical coherence tomography (OCT) is an imaging biomarker for neurodegeneration in multiple sclerosis (MS). In order to become validated as an outcome measure in multicenter studies, reliable quality control (QC) criteria with high ...
Prejaas Tewarie   +6 more
doaj   +1 more source

All‐in‐One Analog AI Hardware: On‐Chip Training and Inference with Conductive‐Metal‐Oxide/HfOx ReRAM Devices

open access: yesAdvanced Functional Materials, EarlyView.
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy