Results 11 to 20 of about 83,806 (94)

Qualitative and quantitative assessment of the effect of respiratory movement on right lung tumors in PET/CT images [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2020
For specific clinical diagnoses, positron emission tomography (PET) can detect more sites of disease than conventional anatomical imaging such as x-ray computed tomography (CT) or magnetic resonance imaging (MRI).
F. Gholami   +4 more
doaj   +1 more source

Radiation damage and yield strength calculations in the pressure vessel of WWER-1000 reactor and sensitivity analysis of neutron spectrum on the shield of vessel [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2021
Radiation damage calculation is very important for estimating the lifetime of nuclear power plant instruments. The purpose of the present study is to evaluate the sensitivity of the damage values to the neutron group energy, where the neutron flux rate ...
E. Moslemi-Mehni   +3 more
doaj   +1 more source

Contrast evaluation of digital industrial radiography images using FLUKA simulation [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2020
Monte Carlo method is widely used for simulation of industrial and medical radiography due to its powerful ability to simulate statistical phenomena such as radiation generation and transport, and detection processes.
M. Khodakarami   +2 more
doaj   +1 more source

Parametric studies for a gas centrifuge using numerical method in OpenFOAM [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2021
In order to increase the performance of a gas centrifuge used in the uranium enrichment industry, the gas flow field inside it is studied and simulated.
V. Ghazanfari   +4 more
doaj   +1 more source

Measuring the temperature variation of refractive index of water by digital interferometry for manufacturing an optical dosimeter [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2020
Using coherent light sources for manufacturing optical dosimeters is of considerable interest. Optical dosimeters are mostly employed for radiotherapy applications; where knowing the temperature dependency of refractive index of the used material in the ...
S. Salimi Meidanshahi   +3 more
doaj   +1 more source

Favorable experimental conditions for differential cross-section measurement of PIGE reactions using the van de graaff accelerator of tehran [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2021
The present research aims to measure the physical parameters affecting the differential cross-sections of PIGE reactions in the 45˚R beamline of the Van de Graaff accelerator.
A. Jokar, O. Kakuee, M. Lamehi-Rachti
doaj   +1 more source

Effects of sewage sludge irradiation on uptake of macronutrients and sodium in basil plant under greenhouse conditions [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2020
Effects of 0, 15, 30 and 60 g per kg of sewage sludge exposed to gamma irradiation at doses of 0, 5, 10 and 20 kGy were investigated on macronutrients and sodium uptakes in the basil root and shoot. The results showed that using 15 and 30 g sewage sludge
B. Asgari Lajayer   +4 more
doaj   +1 more source

Image reconstruction of proton computed tomography modelled by Geant4 Monte Carlo toolkit [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2021
Accuracy in the treatment planning of proton therapy depends on the accuracy of the information used to calculate the relative stopping power of tissues in the patient's body.
E. Alibeigi   +3 more
doaj   +1 more source

Carbon therapy of brain tumors and the effect of phantom compositions on dose calculations using Monte Carlo simulations [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2021
Due to the unique properties of carbons in depth-dose deposition, this study investigated the carbon therapy of brain tumors using the Geant4 toolkit. To see the effect of phantom material on the dose calculations, three phantoms consisting of realistic ...
M. Ahmadi   +2 more
doaj   +1 more source

Simulation of two-phase flow drift flux model in a vertical channel using Newton–Krylov method [PDF]

open access: yesمجله علوم و فنون هسته‌ای, 2021
In the present work, a numerical method is proposed in order to model the subcooled boiling flow in a vertical channel using the Drift Flux Model. The system of nonlinear equations is solved with the fully-implicit scheme using the Jacobian-free Newton ...
H. Esmaili   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy