Results 161 to 170 of about 1,757 (192)
Some of the next articles are maybe not open access.
Journal of Chemical & Engineering Data, 2018
The vapor–liquid equilibria (VLE) data of R1234yf + NMP and R1234yf + DMETrEG were measured at the temperature range of 293.15–353.15 K in a dual cycle experimental apparatus. The thermodynamic consistency of the VLE data was checked with an area test. The VLE data were correlated by the nonrandom two-liquid model, and the results showed that they had ...
Yibo Fang +5 more
openaire +1 more source
The vapor–liquid equilibria (VLE) data of R1234yf + NMP and R1234yf + DMETrEG were measured at the temperature range of 293.15–353.15 K in a dual cycle experimental apparatus. The thermodynamic consistency of the VLE data was checked with an area test. The VLE data were correlated by the nonrandom two-liquid model, and the results showed that they had ...
Yibo Fang +5 more
openaire +1 more source
2021
Bu çalışmada; soğutucu akışkan olarak R134a kullanılan bir Buhar Sıkıştırmalı Soğutma Sisteminde (BSSS’de), R134a’nın alternatifi olarak değerlendirilen R1234yf soğutucu akışkanı, Al2O3 ve Karbon Nanotüp (CNTs) nanoparçacıklarının katkısıyla iş akışkanı olarak kullanılmıştır.
BİLEN, Kemal +2 more
openaire +1 more source
Bu çalışmada; soğutucu akışkan olarak R134a kullanılan bir Buhar Sıkıştırmalı Soğutma Sisteminde (BSSS’de), R134a’nın alternatifi olarak değerlendirilen R1234yf soğutucu akışkanı, Al2O3 ve Karbon Nanotüp (CNTs) nanoparçacıklarının katkısıyla iş akışkanı olarak kullanılmıştır.
BİLEN, Kemal +2 more
openaire +1 more source
Internal Heat Exchanger System Integration for R1234yf Refrigerant
SAE International Journal of Materials and Manufacturing, 2011<div class="section abstract"><div class="htmlview paragraph">This paper will examine a mobile air conditioning (MAC) system optimized for efficiency as well as evaporator cooling capacity. Different internal heat exchanger (IHX) capacities and various thermostatic expansion valve (TXV) parameters will be applied using R1234yf refrigerant ...
Lothar Seybold +2 more
openaire +1 more source
Combustion characteristic of 2,3,3,3-tetrafluroropropene (R1234yf)
International Journal of Refrigeration, 2022Rui Zhai +4 more
openaire +1 more source
R1234yf Einführung mit Hindernissen
ATZ - Automobiltechnische Zeitschrift, 2012Enrique Peral-Antunez, Roland Schedel
openaire +1 more source
Comparative Energy Analysis of R1234yf and R134a Refrigerants
2023Vanita Wagh, A. D. Parekh
openaire +1 more source
R134a and R1234yf Refrigerant Charge Determination Test Method
<div class="section abstract"> <div class="htmlview paragraph">The purpose of this document is to establish guidelines for determining the critical R134a and R1234yf refrigerant charge for off-road, self-propelled work machines as defined in SAE J1116 and agricultural tractors as defined in ANSI/ASAE S390.openaire +1 more source
Analiza czynnika chłodniczego R1234yf jako zamiennika R134a
Chłodnictwo, 2014W artykule przedstawiono porównanie dwóch czynników chłodniczych R134a oraz R1234yf. Czynnik R1234yf został zaproponowany jako zamiennik czynnika R134a, dokonano porównania ich własności termodynamicznych oraz sprawdzono wpływ na parametry pracy układu chłodniczego, przy założeniu identycznych warunków pracy parowacza oraz takich samych wartości ...
openaire

