Results 1 to 10 of about 1,212 (176)

Experimental study of an R1234ze(E)/R134a mixture (R450A) as R134a replacement [PDF]

open access: yesInternational Journal of Refrigeration, 2015
The authors thankfully acknowledge "Ministerio de Educacion, Cultura y Deporte" for supporting this work through "Becas y Contratos de Formacion de Profesorado Universitario del Programa Nacional de Formacion de Recursos Humanos de Investigacion del ejercicio 2012".
Joaquin Navarro-Esbrí   +2 more
exaly   +4 more sources

Experimental Analysis of R134a/LPG as Replacement of R134a in a Vapor-Compression Refrigeration System

open access: yesInternational Journal of Air-Conditioning and Refrigeration, 2017
This paper presents an experimental analysis of a vapor compression refrigeration system (VCRS) using the mixture of R134a and LPG with mass fractions of 28:72 as an alternative to R134a. In this work, we compare the energy performance of both refrigerants, R134a/LPG (28:72) and R134a, in a monitored vapor compression refrigeration system under a wide
Jatinder Singh
exaly   +2 more sources

Capture Fluorocarbon and Chlorofluorocarbon from Air Using DUT‐67 for Safety and Semi‐Quantitative Analysis [PDF]

open access: yesAdvanced Science
Fluoro‐ and chlorofluorocabons (FC/CFCs) are important refrigerants, solvents, and fluoropolymers in industry while being toxic and carrying high global warming potential.
Xiao‐Hong Xiong   +9 more
doaj   +2 more sources

Comparison of R134a and R516A’s Performance at Different Air Velocities in Two Evaporator Ejector Cooling System

open access: yesHittite Journal of Science and Engineering, 2023
This study aims experimentally to investigate the performance parameters of R134a and the alternative R516A refrigerant in two evaporator ejector cooling system (DEES) at different air velocities of evaporator#1.
Mahmut Cüneyt Kahraman   +2 more
doaj   +1 more source

The viscosity of liquid R134a [PDF]

open access: yesInternational Journal of Thermophysics, 1993
The paper reports new measurements of the viscosity of liquid R134a over the temperature range 235 to 343 K and pressures up to 50 MPa. The measurements have been carried out in a vibrating-wire viscometer calibrated with respect to the viscosity of several liquid hydrocarbons. It is estimated that the uncertainty in the viscosity data reported is ±0.6%
C. M. B. P. Oliveira, W. A. Wakeham
openaire   +1 more source

Evaluation of The Use R450A as an Alternative to R134a in Low and Medium Temperature Heat Pump Systems: 4-E (Energy, Exergy, Environmental and Enviro-Economic) Analysis

open access: yesJournal of Advanced Research in Natural and Applied Sciences, 2021
This investigation presents a theoretical evaluation of the use R450A replace to R134a in the low and medium temperature heat pump systems. The energy, exergy, environmental and enviro-economic analyzes of heat pumps have been performed for two ...
Ragıp Yıldırım
doaj   +1 more source

Experimental study on phase change heat transfer cooling plate for multiple heat sources cooling with high heat flux

open access: yesXi'an Gongcheng Daxue xuebao, 2023
In view of the heat dissipation of electronic components with high heat flux, five phase change heat transfer cold plates with different structures and processing methods were designed, the effects of cold plate structural parameters, heat flux ...
LIU Kai   +4 more
doaj   +1 more source

Energetic and exergetic performance comparison of an experimental automotive air conditioning system

open access: yesJournal of Thermal Engineering, 2021
In this study, the energetic and exergetic performance merits of an automotive air condition-ing (AAC) system using R134a and R1234yf have been investigated.
Alpaslan ALKAN, Ahmet KOLIP, Murat HOSOZ
doaj   +1 more source

Performance Evaluation of Centrifugal Refrigeration Compressor Using R1234yf and R1234ze(E) as Drop-In Replacements for R134a Refrigerant

open access: yesEnergies, 2022
With the increasing global requirements for environmental protection, refrigerants with ODP of 0 and low GWP are widely concerned and applied. In this paper, the CFD numerical method simulates the R134a centrifugal compressor directly replaced by R1234yf
Kexin Yi   +5 more
doaj   +1 more source

Theoretical analysis of a Low GWP Refrigerants as a Drop in substitute of R134a in a Domestic Refrigerator [PDF]

open access: yesIranica Journal of Energy and Environment, 2018
Now a days Fridges and Air-conditioners are mostly used in domestic environment. The CFCs have been almost ruled out since 1995 due to their huge impact on the ozone layer, due to the above problem HFC refrigerants are introduced but these are having a ...
M. Shaik Sk, K. Srinivas
doaj   +1 more source

Home - About - Disclaimer - Privacy