Results 1 to 10 of about 103 (63)

Drop-In Replacement of R134a in a Household Refrigerator With Low-GWP Refrigerants R513A, R516A, and R1234ze(E)

open access: yesEnergies, 2023
This study proposes the experimental evaluation of alternative refrigerants with low global warming potentials (GWPs) such as R1234ze(E), R513A, and the mixture R516A as a drop-in replacement for R134a in a domestic refrigerator with a volumetric ...
Juan J G Pabon   +2 more
exaly   +5 more sources

Comparison of R134a and R516A’s Performance at Different Air Velocities in Two Evaporator Ejector Cooling System [PDF]

open access: yesHittite Journal of Science & Engineering, 2023
This study aims experimentally to investigate the performance parameters of R134a and the alternative R516A refrigerant in two evaporator ejector cooling system (DEES) at different air velocities of evaporator#1.
Mehmet Direk   +2 more
exaly   +6 more sources

Volumetric Efficiency Evaluation of the Use of Refrigerants R445a, R515a, R456a, ND, and R516a With Low GWP Instead of R134a

open access: yesJournal of the Institute of Science and Technology, 2021
In this study, the performance of different refrigerants (with low GWP value) depending on thermophysical properties in the cooling system was evaluated. The cooling capacities of R134a, R445a, R515a, R456a, ND, and R516a refrigerants used in the cooling system are determined per unit refrigerant.
Mehmet Direk   +2 more
exaly   +5 more sources

Experimental drop-in comparison of R516A and R134A for water-to-water refrigeration applications [PDF]

open access: yesLibro de actas XI Congreso Ibérico y IX Congreso Iberoamericano de Ciencias y Técnicas del Frío Cytef2022. Avances en Ciencias y Técnicas del Frío - 11, 2023
R134a is still one of the most used hydrofluorocarbons (HFCs) in refrigeration and air conditioning applications. However, it should be phased out in the coming years because of its high global warming potential (GWP). The refrigeration sector needs to find as soon as possible technically suitable alternative refrigerants.
Al-Sayyab, Ali Khalid Shaker   +3 more
core   +8 more sources

Analyzing the carbon dioxide emissions of R134a alternatives in water-cooled centrifugal chillers using the life cycle climate performance framework [PDF]

open access: yesFrontiers in Energy Research, 2023
Introduction: To reduce greenhouse gases, the Kigali Amendment to the Montreal Protocol seeks a phasedown of hydrofluorocarbons. R134a alternatives were analyzed for use in a water-cooled chiller: R450A, R513A, R516A, R1234ze (E), R515A, and R515B ...
Michael O. Akinseloyin   +4 more
doaj   +2 more sources

Roles of the highly conserved amino acids in the second receptor binding site of the Newcastle disease virus HN protein [PDF]

open access: yesVirology Journal, 2019
Background The paramyxovirus haemagglutinin-neuraminidase (HN) is a multifunctional protein that is responsible for attachment to receptors, removal of receptors from infected cells to prevent viral self-aggregation (neuraminidase, NA) and fusion ...
Yaqing Liu   +7 more
doaj   +2 more sources

Experimental drop-in comparison of R516A for water-to-water refrigeration applications

open access: yes, 2022
Ponència presentada al XI Congreso Ibérico y IX Congreso Iberoamericano de Ciencias y Técnicas del Frío Cytef2022. Cartagena (Spain), 17-19 abril, 2022.
Al-Sayyab, Ali   +3 more
core   +3 more sources

Estudio experimental de los refrigerantes R1234ze(E) y R516A para el reemplazo del R134a en un refrigerador doméstico

open access: yesActa Universitaria, 2023
Este trabajo presenta la viabilidad de los refrigerantes R1234ze(E) y R516A para ser usados en la refrigeración doméstica como reemplazo directo del R134a. Se evaluó un refrigerador doméstico instrumentado con el fin de caracterizar su desempeño. Se definió la carga óptima de refrigerante a través del mínimo consumo de energía, resultando una carga de ...
Juan Manuel Belman Flores   +5 more
exaly   +2 more sources

4E Analysis of Alternative Configurations in Mobile Air Conditioning Used in Electromobility and Conventional Vehicles

open access: yesApplied Sciences
This study analyzes four alternative cycle configurations for the traditional vapor compression system used in conventional, hybrid, and electric vehicles, taking low-GWP alternatives for the substitution of R134a.
D. Méndez-Méndez   +4 more
doaj   +2 more sources

Comparative Research on Performances of R516A and R134a in Water-Cooled Chillers

open access: yesZhileng xuebao
R516A is one of the new substitutes for R134a refrigerant in water-cooled chillers. The COP (coefficient of performance) and discharge temperatures of R516A and R134a are compared through a single-stage vapor compression cycle. Under nominal and variable
Li Xiongya, Hua Xue, Guo Xiaolin
doaj   +1 more source

Home - About - Disclaimer - Privacy