Energy and Exergy Analysis of Chest Freezer Using R134a and R290 as Working Fluids Based on Experimental Data [PDF]

open access: yes
Although R134a has a very high global warming (GWP) effect, it is still used as a refrigerant in chest freezers. As an alternative to R134a is R290 which has a very low GWP value, which is only 3.
Hidayat, Syarif   +5 more
core   +2 more sources

Bewertung alternativer Arbeitsmittel für Wärmepumpen im Gebäudesektor [PDF]

open access: yes, 2022
ZusammenfassungDas Arbeitsmittel in Wärmepumpen unterliegt einer Vielzahl von Anforderungen, welche für einen effizienten und sicheren Betrieb eingehalten werden müssen.
Christian Vering   +3 more
core   +1 more source

Heating and cooling challenges for electric vehicles: A comprehensive experimental study [PDF]

open access: yes
An efficient mobile air conditioning (MAC) system using a safe and climate-friendly refrigerant is necessary for human comfort, increases the vehicle's energy performance, and reduces fuel/electricity consumption.
Al-Sayyab, Ali   +3 more
core   +1 more source

Estudio de refrigerantes alternativos al R404A para aplicaciones de refrigeración comercial [PDF]

open access: yes, 2018
Treball final de Grau en Enginyeria Mecànica. Codi: EM1047. Curs acadèmic 2017/2018Con la aprobación del Reglamento Europeo nº 517/2014, comúnmente conocido como FGas, se limita altamente el uso de refrigerantes con altos índices de contaminación ...
Calleja-Anta, Daniel
core  

Experimental Assessment of the Internal Heat Exchanger in Vapour Compression Systems With Low GWP Refrigerant R516A

open access: yes, 2022
Ponència presentada en: 14th International Conference of Applied Energy, Bochum, 8-12, August, 2022.Internal heat exchangers (IHX) are commonly used to improve the energy performance of vapour compression refrigeration cycles.
Al-Sayyab, Ali Khalid Shaker   +5 more
core   +1 more source

DataSheet1_Analyzing the carbon dioxide emissions of R134a alternatives in water-cooled centrifugal chillers using the life cycle climate performance framework.pdf

open access: yes, 2023
Introduction: To reduce greenhouse gases, the Kigali Amendment to the Montreal Protocol seeks a phasedown of hydrofluorocarbons. R134a alternatives were analyzed for use in a water-cooled chiller: R450A, R513A, R516A, R1234ze (E), R515A, and R515B ...
Carter Hall (17584866)   +4 more
core   +1 more source

Energy analysis of low-GWP refrigerants R513A and R516A as alternatives to R134a in heat pumps for simultaneous heating and cooling of water [PDF]

open access: yes
The transition to low global warming potential (GWP) refrigerants is essential in addressing climate change. This study evaluates the energy performance of low-GWP refrigerants R513A and R516A as alternatives to R134a in heat pump systems for ...
ONYEBUCHI, Okafor Geoffrey
core  

Analyse énergétique, exergétique et environnementale (3E) d'une pompe à chaleur composée à éjecteur fonctionnant avec des frigorigènes à faible PRP pour le refroidissement d'un centre de données et le chauffage urbain simultanés

open access: yes, 2021
This work presents an energy, exergy, and environmental evaluation of a novel compound PV/T (photovoltaic thermal) waste heat driven ejector-heat pump system for simultaneous data center cooling and waste heat recovery for district heating networks.
Al-Sayyab, Ali   +2 more
core   +1 more source