Results 91 to 100 of about 1,757 (201)

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

open access: yes, 2014
The Montreal protocol and Kyoto protocol underlined the need of substitution of CFC’s and HCFC’s due to their adverse impact on atmospheric ozone layer which protects earth from U.V rays.
P. R. Tailor, A. D. Parekh
core   +2 more sources

Leakage Research of Split-type Air-conditioner using R290 as Refrigerant

open access: yesZhileng xuebao, 2013
The ozone depletion potential (ODP) and global warming potential (GWP) of HCFCs and HFCs are higher than hydrocarbons (HCs). R290 is perfect in environmental protection and energy saving performance.
张网   +4 more
doaj  

Performance of heat pumps charged with R170/R290 mixture

open access: yes
In this study, thermodynamic performance of R170/R290 mixture is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5 kW.
Park, Ki-Jung, Jung, Dongsoo
core  

Comparison of Tribological Characteristics of Vane-piston Interface between R290 and R410A in Rotary Compressor

open access: yesZhileng xuebao, 2018
R290 has been considered for use in air-conditioning systems as a low global warming potential (GWP) refrigerant. This paper describes the tribological characteristic of the vane-piston tribopair in a R290 rotary compressor. For the purpose of simulating
Chen Zhenhua, Li Gaimin, Wu Jianhua
doaj  

Assessing the decarbonization potential of new generation R290 high-temperature heat pumps for apartment buildings [PDF]

open access: yes
Electricity driven heat pumps, especially the air-to-water ones, represent a key technology for the decarbonization of existing residential buildings. In particular, new R290 (propane) heat pumps represent a valuable solution for substituting existing ...
Ferrara, Maria   +3 more
core   +1 more source

Energetic, economic and environmental (3E) analysis of R290, R454C and R465A for drop-in split type air conditioning running on R22

open access: yesCase Studies in Thermal Engineering
The present study aims to evaluate the process of drop-in of R22 in split type air conditioning with refrigerant fluids R290, R454C, and R465A. A mathematical model was developed to do an energetic, economic and environmental analysis using different ...
Carlos H.M. Braga   +4 more
doaj   +1 more source

Performance of Air Cooled Heat Pump Air Conditioner with Natural Refrigerant R1270 and R290 to Replace R22

open access: yes, 2011
A natural and environment friendly refrigerant propylene and propane are proposed as the substitute of R22 in air conditioner. The experiments were respectively conducted on an existing enthalpy potential lab.
He Li, Ling Xi, Jian Bo Chen
core   +1 more source

Home - About - Disclaimer - Privacy