Results 71 to 80 of about 1,757 (201)

Analisi sperimentale delle prestazioni di macchine produttrici di ghiaccio operanti con R290 [PDF]

open access: yes, 2018
LAUREA MAGISTRALEQuesto lavoro di tesi si focalizza sulla sostituzione di refrigeranti HFC con l’idrocarburo propano, R290. In particolare, sono analizzate sperimentalmente le prestazioni di tre macchine per la produzione di ghiaccio a cubetti operanti ...
ZANZOTTERA, SERGIO
core  

Experimental Research on Performance of Room Air Conditioner with Alternative Refrigerants at High Ambient Temperature

open access: yesZhileng xuebao, 2018
Alternative refrigerants such as R290 and R32 are gradually being applied to room air conditioners (RACs). This study tested the performances of R290, R22, R410A, and R32 in the same system.
Liu Zhen, Hu Maojuan, Li Tingxun
doaj  

Development of Alternative Binary Mixtures to Replace HFC 134a in Domestic Refrigerator

open access: yesChemical Engineering Transactions, 2018
Thermodynamic and volumetric properties of alternate Refrigerant mixtures to replace R134a have been predicted using SRK EOS and modified PSRK mixing rule using UNIFAC method.
Parashurama Siddegowda   +2 more
doaj   +1 more source

A PERFORMANCE OF A WINDOW AIR CONDITIONER USING ALTERNATIVE REFRIGERANTS R22 AND R290

open access: yes, 2016
<p>In this paper, simulation studies of a one TR window air conditioner were carried out with three different mixtures of R22 and R290 M1 (50-50) %, M2 (25-75) % and M3 (75-25) %.
Dr. B. Sachuthananthan,*, T. Naresh Kumar, A.Muthu Manokar
core   +1 more source

Experimental Study of a New Hydrocarbon Mixture for Domestic Re-frigerator to Replace R134a

open access: yesITEGAM-JETIA
In a domestic refrigerator with 4.49cc displacement compressors, the performance of R290 (48 by mass percent) and R600a (52 by mass percent) was examined experimentally. In our research, we employed a 210-litre refrigerator designed to run on R12 with a
Anjappa S B, parashurama s, Ramesha D K
doaj   +1 more source

Performance comparativa entre R290/R600a (50:50) e R134a para drop-in em refrigerador doméstico [PDF]

open access: yes, 2010
This research this based on the seminar on Use of Natural Fluids in Refrigeration and Air-Conditioning Systems conducted in 2007 in Sao Paulo. The event was inserted in the National Plan for Elimination of CFCs, coordinated by the Ministry of ...
Almeida, Igor Marcel Gomes
core  

Experimental and theoretical examination of the energy performance and CO2 emissions of room air conditioners utilizing natural refrigerant R290 as a substitute for R22

open access: yes, 2023
The purpose of this research is to analyze the performance of an air conditioner that uses natural refrigerant R290 both analytically and experimentally. The feasibility of R290 for R22 air conditioner is examined thoroughly.
Ali A. Rajhi   +11 more
core   +1 more source

Simulation Analysis and Experimental Study on Substituting R134a with R290 in Electric Vehicle Compressors

open access: yesZhileng xuebao
Because the driving method of electric vehicles differs from that of conventional ones, the power sources of electric vehicles can be diversified. The Global Warming Potential (GWP) and ozone depletion potential (ODP) values of the refrigerant R290 are ...
Chen Jianhong   +5 more
doaj  

Performance computation of window air conditioner with very low GWP near azeotropic refrigerant mixtures as a drop in Substitutes to R22

open access: yesMATEC Web of Conferences, 2018
The principal objective of the present study is to compute the thermodynamic performance of window air conditioner based on standard vapour compression refrigeration cycle using R22, R407C and nineteen refrigerant mixtures.
Vali Shaik Sharmas   +2 more
doaj   +1 more source

Analisis Performansi Sistem Water Chiller Setelah Proses Retrofit R22 menjadi R290 dengan Variasi Massa Pengisian R290

open access: yesProsiding Industrial Research Workshop and National Seminar
Hidrokarbon merupakan refrigeran alami yang memiliki dampak lingkungan yang jauh lebih rendah dibandingkan refrigeran hydrochlorofluorocarbons (HCFC) dan hydrofluorocarbon (HFC). Penggunaan R290 sebagai refrigeran alternatif dan ramah lingkungan dilakukan karena memiliki nilai ozone depletion potential (ODP) nol dan global warming potential (GWP) yang ...
Sandy Karan   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy