Exergy Analysis of Tita nium Dioxide (TiO2) Suspended with R290/R600 as a Substitute for R134a [PDF]
Synthetic refrigerants are being phased out gradually in accordance with international environmental protection protocols because of global warming and ozone layer depletion.
D.M. Madyira, T.O. Babarinde
doaj +3 more sources
Comparative Analysis of the Environmental Load of Natural Refrigerant (R290)
Due to the detrimental environmental consequences of synthetic refrigerants, natural refrigerants have gained renewed interest as alternative refrigerants for a variety of applications due to their minimal ozone depletion potential (ODP) and insignificant global warming potential (GWP).
Houria Bouzghiba, Gábor Géczi
openaire +2 more sources
Design and Analysis of Charge‐Reduced Refrigerant Cycles Using R290 [PDF]
AbstractR290 is one of the most promising refrigerants for heat pumps and cooling processes working in a temperature range of –15 to 70 °C. The nearly neglectable global warming potential and attractive thermodynamic properties allow the design of climate‐friendly and efficient refrigeration systems and heat pumps.
Schnabel, Lena +4 more
openaire +4 more sources
Research on the Flammability Limits of R1234yf/R290 and R1234ze(E)/R290 Mixtures
Propane (R290) is a potential refrigerant substitute for household air conditioners. However, its flammability limits its application. In this study, the flammability limits of R290, 2,3,3,3-tetrafluoropropene (R1234yf), trans-1,3,3,3-tetrafluoropropene (
Shen Jun +5 more
doaj +2 more sources
This study addresses the experimental performance of the alternative refrigerant R290 in the R22 low-temperature heat pump system. Results show that when R22 was directly replaced by R290 in the original system, both the heat exchange and coefficient of ...
Zhang Yun +5 more
doaj +2 more sources
Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290
An original R410A wall room air conditioner was retrofitted with R290 for performance experiments. The R410A wall room air conditioner has a COP and a refrigerating capacity 6.0597and 1929.3 W respectively.
Fajar TK Berkah +1 more
doaj +2 more sources
Due to the high energy consumption of refrigerated display cabinets used in supermarkets, a life cycle cooling performance analysis to increase energy efficiency and reduce environmental impacts is the main subject of this study.
Havva Demirpolat +4 more
doaj +2 more sources
Experimental Research on Performance of Small Room Air Conditioner with R290
The performance of small room air conditioners using R290 as a substitute for R22 was studied in this study.Tests were conducted for a KF-26GW/K air conditioner and a high EER KFR-27GW/E air conditioner.The charging quantity,the lengths of single ...
肖洪海, 张桃, 胡艳
doaj +4 more sources
Analysis and Comparison of the Refrigeration Cycle Performance of R290 Direct Contact Condensation
In the study, thermal performances of direct contact condensation refrigeration cycle with R290 were analyzed and compared with conventional one stage compression refrigeration cycle with R290. The following conclusions are obtained.
Ning Jinghong +3 more
doaj +2 more sources
Design of heat pump system for a railway train’s cabin applications utilizing R744 and R290
Among greenhouse gases, R-134a, commonly used in train HVAC systems, has a high global warming potential (GWP) of 1430. Korea is required to reduce R-134a usage by 80% by 2045, necessitating the development of eco-friendly alternatives.
Minji Kwon, Rin Yun, Hisuk Kim
doaj +2 more sources