Results 31 to 40 of about 1,757 (201)
Performance analysis of solar milk refrigerator using energy efficient R290
In this paper, an experimental investigation on the performance of vapor-compression based milk refrigerator using R290 as refrigerant is carried out. Milk refrigerator is driven by solar photovoltaic.
Shailendra Kasera +2 more
doaj +1 more source
Boiling Heat Transfer Coefficients of R290 in Tubes
Abstract In 2016, Montreal Protocol Kigali Amendment stipulated that developed countries should reduce the consumption and production of HFCs from 2019 and that developing countries should start the reduction in 2029. New alternative refrigerants should have lower GWP to reduce negative effects on the environment.
openaire +1 more source
Thermodynamic screening of alternative refrigerants for R290 and R600a
Due to Regulation EU 517/2014 (F-Gas), the use of refrigerants with GWP higher than 150 was limited from 2015 on in small capacity refrigeration systems in Europe. Although refrigerants that dominate are R600a and R290 nowadays, which are classified as A3 by ASHRAE 34, literature points out that some refrigerant mixtures exist that could offer benefits
Daniel Calleja-Anta +5 more
openaire +3 more sources
Energy Performance Analysis of a Solar Refrigerator Using Ecological Refrigerants
The development of sustainable energy technologies must be a priority given the rising global energy demand and global warming gases emission. In this work, the energy evaluation of a small-capacity direct-current refrigerator with internal heat exchange
Carlos Amaris +2 more
doaj +1 more source
Surface Tension of R290/Lubricant Oil Mixtures from 243 to 333 K
Propane (R290) is a promising natural refrigerant with zero ODP and very low GWP. The surface tension of a refrigerant/oil mixture is of importance for its capillary flow rate, wettability, and heat transfer performance.
Xiaopo Wang (828731) +2 more
core +1 more source
Performance analysis of a zeotropic mixture ( R290/CO2) for trans-critical power cycle
Low critical temperature limits the application of CO2 trans-critical power cycle. The binary mixture of R290/CO2 has higher critical temperature. Using mixture fluid may solve the problem that subcritical CO2 is hardly condensed by conventional cooling ...
Wei XL(魏小林) +3 more
core +1 more source
Experimental Analysis of Alternate Refrigerant Mixtures in Refrigeration System [PDF]
This study focuses on conducting experimental analyses to assess the impact of alternative refrigerant blends within a vapor compression refrigeration system, with the aim of replacing the existing R134a refrigerant.
R Ragavendiran +6 more
doaj +1 more source
ABSTRACT Compact plate‐fin heat exchangers (PFHEs) are commonly utilized in diverse industries, including aerospace, automotive, processing, and space. Various fin configurations, such as Plain fins, Wavy fins, Lance and Offset fins (OSFs), Perforated fins, louvered fins, and pin fins, are employed in compact heat exchangers (CHEs).
Chennu Ranganayakulu
wiley +1 more source
Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr
R290 is a type of natural refrigerant that has ODP = 0 and GWP = 4. While R32 from synthetic materials has ODP= 0 and GWP = 675 both are refrigerants used in Split AC. With this high GWP, it can have a damaging impact on the atmosphere.
null Syafrizal +11 more
core +1 more source
Abstract Understanding the genome‐wide diversity of jute mallow (Corchorus olitorius L.) is crucial for unlocking the potential of global genebank collections, enabling the discovery and use of traits that support climate resilience, improve nutrition, and increase productivity.
Abdul J. Shango +11 more
wiley +1 more source

