Results 131 to 140 of about 7,149 (164)
Some of the next articles are maybe not open access.
Oral Therapy for Experimental Coccidioidomycosis with R41 400 (Ketoconazole), a New Imidazole
The American Review of Respiratory Disease, 1978Abstract Oral treatment of mice with R41 400, ketoconazole, after intranasal challenge with arthrospores of Coccidioides immitis prevented death at doses of 40 mg per kg of body weight per day. Doses of 160 mg per kg of body weight per day during 50 to 100 days eradicated the fungus from the lungs, liver, spleen, and kidneys of ...
H B Levine, J M Cobb
exaly +3 more sources
Applied Thermal Engineering, 2017
Abstract In this study, blend of CO2 with R41 is evaluated for application in three different systems including a refrigerated cabinet, an air-source heat pump water heater and a water-source heat pump water heater. The effects of CO2/R41 mixture as an azeotropy refrigerant on system performance are analyzed under various working conditions.
Yuehong Lu
exaly +2 more sources
Abstract In this study, blend of CO2 with R41 is evaluated for application in three different systems including a refrigerated cabinet, an air-source heat pump water heater and a water-source heat pump water heater. The effects of CO2/R41 mixture as an azeotropy refrigerant on system performance are analyzed under various working conditions.
Yuehong Lu
exaly +2 more sources
Applied Energy, 2016
Abstract This study presents a comparative analysis of thermodynamic performance of cascade refrigeration systems (CRSs) for refrigerant couples R41/R404A and R23/R404A to discover whether R41 is a suitable substitute for R23. The discharge temperature, input power of the compressor, coefficient of performance (COP), exergy loss (X) and exergy ...
Zhili Sun, Youcai Liang
exaly +3 more sources
Abstract This study presents a comparative analysis of thermodynamic performance of cascade refrigeration systems (CRSs) for refrigerant couples R41/R404A and R23/R404A to discover whether R41 is a suitable substitute for R23. The discharge temperature, input power of the compressor, coefficient of performance (COP), exergy loss (X) and exergy ...
Zhili Sun, Youcai Liang
exaly +3 more sources
Investigation on the environmental impact of R32, R152a and R41 refrigerant blends
Engineering Research Express, 2023Abstract The improper usage of refrigerants has a drastic impact on the environment, which is contributing to global warming and ozone layer depletion. The refrigerants which are being used currently have a very high GWP (Global Warming Potential) value that signifies an adverse impact on global warming.
M S Kiran Karthik +7 more
openaire +1 more source
2023
The Minor Planet Electronic Circulars contain information on unusual minor planets, routine data on comets and natural satellites, and occasional editorial announcements. They are published on behalf of Division F of the International Astronomical Union by the Minor Planet Center, Smithsonian Astrophysical Observatory, Cambridge, MA 02138, U.S.A.
openaire +1 more source
The Minor Planet Electronic Circulars contain information on unusual minor planets, routine data on comets and natural satellites, and occasional editorial announcements. They are published on behalf of Division F of the International Astronomical Union by the Minor Planet Center, Smithsonian Astrophysical Observatory, Cambridge, MA 02138, U.S.A.
openaire +1 more source
Volume 3B: Oil and Gas Applications; Organic Rankine Cycle Power Systems; Supercritical CO2 Power Cycles; Wind Energy, 2014
The performances of the transcritical Rankine cycles using R41 and CO2 as working fluids for power generation with lower temperature renewable energy are analyzed respectively and presented in this paper. The results show that the R41 cycle displays better comprehensive performance than that of the CO2 cycle.
Jixiang Liao, Qun Zheng
openaire +1 more source
The performances of the transcritical Rankine cycles using R41 and CO2 as working fluids for power generation with lower temperature renewable energy are analyzed respectively and presented in this paper. The results show that the R41 cycle displays better comprehensive performance than that of the CO2 cycle.
Jixiang Liao, Qun Zheng
openaire +1 more source
Heat and Mass Transfer, 2018
A numerical study of cascade refrigeration system using two different refrigerant pairs, namely, R41–R404A and R170–R161 working under the same operating conditions has been presented in this paper. A computer code has been developed in Engineering Equation Solver software using the basic energy and exergy equations of cascade refrigeration system ...
Ranendra Roy, Bijan Kumar Mandal
openaire +1 more source
A numerical study of cascade refrigeration system using two different refrigerant pairs, namely, R41–R404A and R170–R161 working under the same operating conditions has been presented in this paper. A computer code has been developed in Engineering Equation Solver software using the basic energy and exergy equations of cascade refrigeration system ...
Ranendra Roy, Bijan Kumar Mandal
openaire +1 more source

