Results 41 to 50 of about 1,734 (150)
Cycloplegic Effects on the Cylindrical Components of the Refraction
It is important to predict which astigmatic patients require separate refraction for near vision. This study compared cylindrical components changes by cyclopentolate 1% for the low and high amount of astigmatism. The right eyes of 1014 healthy individuals (307 males and 707 females) with cylindrical refractive power more than −0.5 diopter on ...
Athar Zareei +3 more
wiley +1 more source
The front part of the eye is exposed to the surface of the body, making it susceptible to injury. Blunt eye injuries often destroy the tissue structure in the anterior part of the eye. Often there is detachment of the iris root, separation of the ciliary body, the angle of retraction of the chamber, and complete dislocation or subluxation of the lens ...
Xiaoli Li, Zhihan Lv
wiley +1 more source
Stability of Refraction During Four Years After Radial Keratotomy in the Prospective Evaluation of Radial Keratotomy Study [PDF]
The Prospective Evaluation of Radial Keratotomy Study is a nine-center clinical trial of a standardized technique of radial keratotomy in 435 patients who had simple myopia with a preoperative refraction between -2.00 and -8.00 diopters.
Lindstrom, Richard D +13 more
core +1 more source
Infection After Radial Keratotomy [PDF]
Eight years after eight-incision radial keratotomy, a corneal ulcer developed around the inferotemporal incision in an otherwise healthy 39-year-old man. There was no history of corneal trauma or contact lens wear.
Jaffe, Mark +3 more
core +1 more source
Management of pterygium in a case of post radial keratotomy [PDF]
<p class="abstract"><span lang="EN-IN">This study is a case of post radial keratotomy who underwent pterygium excision and its management</span>.
Satish Agraharam +3 more
core +1 more source
IOL Power Calculation Features after Radial Keratotomy
IOL power calculation after keratorefractive surgery is an important applied aspect of cataract surgery. The probability of refractive error is especially high when calculating in patients with a history of radial keratotomy. There is no unified approach
A. A. Kasyanov, E. G. Ryzhkova
doaj +1 more source
Purpose: To describe a previously unreported case of reversible myopic shift with corresponding changes in corneal contour in a patient treated with netarsudil/latanoprost.
David Chung, Edward J. Meier
doaj +1 more source
Survey of Ehlers‒Danlos Patients’ ophthalmic surgery experiences
Eye surgery on patients with Ehlers‒Danlos may have a higher complication rate than seen in the general population. Surgeons should be cognizant that the diagnosis of Ehlers‒Danlos might not be made in patients suffering this condition. Abstract Background Ehlers‒Danlos Syndrome (EDS) is a rare disease affecting approximately 1 in 5,000 people ...
Anita Louie +11 more
wiley +1 more source
Complicated flap creation with femtosecond laser after radial keratotomy [PDF]
Purpose: To report a case of laser in situ keratomileusis (LASIK) that used the Intralase femtosecond laser 14 years after radial keratotomy (RK) for residual myopic ...
Cakir, Hanefi +4 more
core +1 more source
Purpose. To check if a regression formula, IOLMaster‐derived, to calculate the real corneal power after photorefractive keratectomy (PRK), can give reliable results utilizing the Pentacam. Methods. Pre‐ and postoperative IOLMaster, Km, and Pentacam K readings were measured.
Maddalena De Bernardo +4 more
wiley +1 more source

