Results 201 to 210 of about 272,094 (281)
Stability of the Baseline Holder in Readout Circuits For Radiation Detectors. [PDF]
Chen Y +8 more
europepmc +1 more source
The integration of photovoltaic (PV) systems into building structures introduces distinct fire risks with critical implications for occupant safety. This review examines the key fire hazards associated with PV implementation and explores mitigation strategies, including flame‐retardant additives.
Florian Ollagnon +7 more
wiley +1 more source
Defect Analysis of the β– to γ–Ga2O3 Phase Transition
The role of defects at all the relevant stages of the β$\beta$‐ to γ$\gamma$‐Ga2O3 polymorph transition is investigated using a multi method approach. The positron annihilation spectroscopy based results show that the defect density decreases after the transition, and that changes in defect configuration within the γ phase occur with increasing ...
Umutcan Bektas +9 more
wiley +1 more source
Automation of Detector Array Design for Baggage X-Ray Scanners. [PDF]
Dmitruk K.
europepmc +1 more source
Shellac, a centuries‐old natural resin, is reimagined as a green material for flexible electronics. When combined with silver nanowires, shellac films deliver transparency, conductivity, and stability against humidity. These results position shellac as a sustainable alternative to synthetic polymers for transparent conductors in next‐generation ...
Rahaf Nafez Hussein +4 more
wiley +1 more source
This study demonstrates that pulsed potential electrolysis significantly improves CO2 reduction performance on copper‐nitrogen doped carbon electrodes. The formation of cationic copper sites and metallic clusters as a function of applied intermittent potential leads to notable selectivity changes compared to potentiostatic reduction.
Dorottya Hursán +13 more
wiley +1 more source
This work presents self‐propelled CRISPR/Cas9‐functionalized Au–MRs for rapid, amplification‐free, “on‐the‐fly” DNA detection. By harnessing motion‐assisted signal recovery, the platform achieved the limit of detection in low fM DNA concentrations, enabling detection across a wide dynamic range within only 5 min, which is significantly faster than any ...
Jyoti +3 more
wiley +1 more source
In Situ Dose Measurements in Brachytherapy Using Scintillation Detectors Based on the Al<sub>2</sub>O<sub>3</sub>:C, Al<sub>2</sub>O<sub>3</sub>:C,Mg, and GAGG:Ce Crystals. [PDF]
Witkiewicz-Lukaszek S +4 more
europepmc +1 more source
Fast‐Responding O2 Gas Sensor Based on Luminescent Europium Metal‐Organic Frameworks (MOF‐76)
Luminescent MOF‐76 materials based on Eu(III) and mixed Eu(III)/Y(III) show rapid and reversible changes in emission intensity in response to O2 with very short response times. The effect is based on triplet quenching of the linker ligands that act as photosensitizers. Average emission lifetimes of a few milliseconds turn out to be mostly unaffected by
Zhenyu Zhao +5 more
wiley +1 more source
Experimental evaluation of silicon carbide P-N detectors under thermal and fast neutron irradiation at the RA-6 nuclear research reactor. [PDF]
Pérez M +6 more
europepmc +1 more source