Impacts of The Radiation Environment At L2 On Bolometers Onboard The Herschel Space Observatory
We present the effects of cosmic rays on the detectors onboard the Herschel satellite. We describe in particular the glitches observed on the two types of cryogenic far- infrared bolometer inside the two instruments PACS and SPIRE.
Boulade, Olivier +9 more
core +1 more source
Measurement of IBD-like background with plastic scintillator detector array at surface level
A prototype detector array for reactor electron antineutrinos is constructed using a 4 × 4 (160 kg) plastic scintillator detector array and operated for 277 h of background data collection.
Chao Wang +6 more
doaj +1 more source
Compton Scattered Transition Radiation from Very High Energy Particles
X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. At energies approaching gamma = E/mc^2 = 10^5, transition radiation detectors (TRDs) can be optimized by using thick (sim 5 - 10 mil) foils with large (5-10 ...
Artru +9 more
core +1 more source
Identification of photons in double beta-decay experiments using segmented germanium detectors - studies with a GERDA Phase II prototype detector [PDF]
The sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external gamma-radiation.
Abt, I. +5 more
core +2 more sources
Progress in 3D Silicon Radiation Detectors
In the past few years, there has been an increasing interest toward 3D silicon radiation detectors. Owing to their unique architecture, 3D detectors provide a remarkable radiation hardness at relatively low bias voltage (hence low power dissipation ...
Gian-Franco Dalla Betta +2 more
doaj +1 more source
A review of advances in pixel detectors for experiments with high rate and radiation
The Large Hadron Collider (LHC) experiments ATLAS and CMS have established hybrid pixel detectors as the instrument of choice for particle tracking and vertexing in high rate and radiation environments, as they operate close to the LHC interaction points.
Garcia-Sciveres, Maurice +1 more
core +2 more sources
Simulation, design and fabrication of large area implanted silicon two-dimensional position sensitive radiation detectors [PDF]
The fabrication process of a two-dimensional position sensitive radiation detector (2-D PSD) with a 4 cm2 active area is presented. Critical steps in the fabrication are emphasised.
Aïte, K. +3 more
core +2 more sources
Capabilities of gamma-spectrometry methods for on-line monitoring of nitride SNF pyrochemical reprocessing [PDF]
The paper reports the first test results for detectors of various types and equipment of gamma-spectrometry channels under external radiation originating from pyrochemical reprocessing of spent mixed nitride uranium-plutonium (MNUP) fuel.
Boris A. Kanashov +12 more
doaj +3 more sources
The aim of this work is to analyze existing detectors for the relative dosimetry of small radiation fields in external beam radiation therapy and the requirements for them, consider the problems in carrying out dosimetry of small radiation fields ...
V. S. Piskunou, I. G. Tarutin
doaj +1 more source
Radiation tests of the Silicon Drift Detectors for LOFT [PDF]
During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the satellite ...
Azzarello, P. +15 more
core +1 more source

