ESTRO-EPTN radiation dosimetry guidelines for the acquisition of proton pencil beam modelling data. [PDF]
Gomà C +11 more
europepmc +1 more source
Obese patient imaging: Potential dose reduction with photon‐counting CT
Abstract Background Photon‐counting CT (PCCT) offers key advantages over energy integrating detector CT (EID‐CT), especially in low‐dose scans and imaging larger patients. As obesity rates rise, minimizing image noise is critical for diagnostic accuracy.
Leening P. Liu +10 more
wiley +1 more source
In vivo assessment of safety, biodistribution, and radiation dosimetry of the [18F]Me4FDG PET-radiotracer in adults. [PDF]
Geist BK +11 more
europepmc +1 more source
Abstract Background Flattening filter‐free (FFF) beams are increasingly deployed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS). The Elekta Versa HD (VHD) and Varian TrueBeam (TB) are the two most widely used FFF‐capable platforms; however, no prior study has compared their 6 MV FFF commissioning parameters under fully ...
Mustafa K. Al‐Aseebee +2 more
wiley +1 more source
Human biodistribution and radiation dosimetry for the tau tracer [18F]Florzolotau in healthy subjects. [PDF]
Lin KJ +4 more
europepmc +1 more source
K‐Edge imaging using a clinical dual‐source photon‐counting CT system
Abstract Background Photon‐counting CT (PCCT) enables K‐edge imaging, an advanced multi‐material decomposition technique that requires multiple energy bins to perform decomposition unconstrained by physical assumptions. The clinical implementation of K‐edge imaging applications like dual‐contrast imaging could lead to reductions in radiation dose and ...
Martin V. Rybertt +8 more
wiley +1 more source
Radiation dosimetry performance appraisal of the optimal concentration of nitro blue tetrazolium dye in PVA composite film at low X-ray doses. [PDF]
Albejadi R +4 more
europepmc +1 more source
Monte carlo assessment of advanced shielding materials for space‐efficient radiotherapy vault design
Abstract Background Conventional radiotherapy vault shielding typically employs 2 to 3 meters of ordinary concrete, consistent with NCRP Report 151 reference data. While NCRP 151 specifies dose‐based design goals rather than mandating particular materials, the practical default of concrete results in vault footprints of 150 to 200 m2 per linac, which ...
Beechui Koo +6 more
wiley +1 more source
Abstract Background Cone‐beam computed tomography (CBCT) is widely used in image‐guided radiotherapy because it reflects the patient's anatomy immediately before treatment. However, CBCT images of the abdominal organs, including the pancreas, are often degraded by respiratory motion.
Airi Nukushina +10 more
wiley +1 more source
Human biodistribution and radiation dosimetry of two novel α-synuclein PET tracers, <sup>18</sup>F-SPAL-T-06 and <sup>18</sup>F-C05-05. [PDF]
Goto R +12 more
europepmc +1 more source