Comparison of the Measurement Uncertainty of Thermoluminescence Dosimeters (TLD-100 and GR-200) in Clinical Radiotherapy Energies [PDF]
Background: Accurate determination of individual radiation doses is critical in dosimetry, and international standards emphasize the importance of reporting measurement uncertainties.
Bahare Sadeghi +4 more
doaj +2 more sources
Performance Characteristics of a New Automatic Chip TLD Reader [PDF]
The TR5500 Thermoluminescent Dosimeter (TLD) reader was specifically designed and developed for the automated and efficient readout of Thermoluminescent (TL) chips and pellets in Iran.
Sajjad Betyar +2 more
doaj +2 more sources
Sensitivity and Performance of Uncooled Avalanche Photodiode for Thermoluminescent Dosimetry Applications [PDF]
Detecting extremely low light signals is the basis of many scientific experiments and measurement techniques. For many years, a high-voltage photomultiplier has been the only practical device used in the visible and infrared spectral range. However, such
Piotr Sobotka +6 more
doaj +2 more sources
Radiation Dose Assessment in Diagnostic Imaging Using Thermoluminescent Dosimeter-100H Dosimeters and a RANDO Phantom: Insights from Chest, Pelvic, and Skull Examinations [PDF]
Purpose: This study aims to evaluate radiation doses to the skin, pelvis, and skull during routine radiographic imaging procedures. Materials and Methods: Entrance skin dose (ESD) was assessed using both direct and indirect methods.
Sedigheh Sina +11 more
doaj +2 more sources
Review of the thermoluminescent dosimetry method for the environmental dose monitoring [PDF]
Passive solid state dosimeters, such as thermoluminescence dosimeters, provide integrated measurement of the total dose and are widely used in environmental monitoring programs. The objective of this paper is to provide a comprehensive review on
Stanković-Petrović Jelena S. +5 more
doaj +1 more source
Assessment of rectal dose with thermoluminescent in vivo dosimetry in high-dose-rate cobalt-60 intracavitary brachytherapy for cervical cancer: A two-arm cohort study using orthogonal images planning [PDF]
Omega Moses Mlawa +3 more
doaj +2 more sources
Evaluation of 3D Printed Anthropomorphic Head Phantom for Calibration of TLD in Eye Lens Dosimeter [PDF]
Background: Calibration of Thermo Luminescent Dosimetry (TLD) in eye lens dosimeter requires a standard phantom. The use of anthropomorphic phantoms in calibration needs evaluation. Objective: This study aimed to analyze the angular response of the TLD
Endarko Endarko +5 more
doaj +1 more source
Workplace monitoring in the Radiation Physics and Metrology Laboratory (LAF-RAM)
The values of environmental equivalent dose H*(10) using thermoluminescent dosimeters (TLD) in the Radiation Physics and Metrology Laboratory (LAF-RAM) from 2019 to 2021 are presented.
Andrea Castillo +2 more
doaj +1 more source
The phosphate glass samples doped with Tb2O3 oxide (general formula: P2O5-Al2O3-Na2O-Tb2O3) were synthesized and studied for usage in high-dose radiation dosimetry (for example, in high-activity nuclear waste disposals).
Andrzej Gasiorowski +2 more
doaj +1 more source
In this work we have investigated the thermoluminescent (TL) response of carbon doped lanthanum aluminate crystals grown by solid state reaction method. We conducted three syntheses by different combinations of Al2O3, La2O3 and 0.1 wt % of carbon atoms.
neriene alves +2 more
doaj +1 more source