Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda   +9 more
wiley   +1 more source

The discrete ordinate method for angular flux calculations in slab geometry

open access: yesHeliyon, 2019
In many deterministic methods, concerning the resolution of the neutron transport equation, a more global and practical representation of the angular flux is needed to provide us with useful and complete information on the neutron population in a reactor
M. Lahdour   +3 more
doaj  

AAPM medical physics practice guideline 13.a: HDR brachytherapy, part B

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The goal of this report is to assist the clinical medical physicist in assuring that key quality standards and practice considerations are met to ensure safe, reliable, and reproducible high dose rate (HDR) brachytherapy (BT) treatment. This guideline has been developed to provide appropriate minimum standards for such services.
Susan L. Richardson   +8 more
wiley   +1 more source

Automated rapidplan model validation using Eclipse scripting API

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma   +2 more
wiley   +1 more source