Results 121 to 130 of about 586 (176)

Exhalation of Rn-219 by patients treated with Radium-223. [PDF]

open access: yesEJNMMI Phys
Wanke C   +3 more
europepmc   +1 more source

In situ measurement of radon and thoron exhalation rate

open access: yesIn situ measurement of radon and thoron exhalation rate
openaire   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Radon Exhalation From Temperature Treated Loess

Science of the Total Environment, 2022
Radon gas is a cancer risk and exists naturally in certain soils, such as loess, which is an important raw earth construction material in arid regions such as northwestern China and southern USA. Accordingly, the radon exhalationed from building materials is of increasing concern; however, there is little research on radon exhalation from loess.
Liyun Tang, Jishi Geng, Qiang Sun
exaly   +3 more sources

Radon in the Exhaled Air of Patients in Radon Therapy

Radiation Protection Dosimetry, 2017
In the Gastein valley, numerous facilities use radon for the treatment of various diseases either by exposure to radon in air or in radon rich thermal water. In this study, six test persons were exposed to radon thermal water in a bathtub and the time-dependent radon activity concentration in the exhaled air was recorded.
Herbert, Lettner   +5 more
openaire   +2 more sources

Radon permeability and radon exhalation of building materials

Science of The Total Environment, 2001
High radon concentrations indoors usually depend on the possibilities of radon penetration from the surrounding soil into the buildings. Radon concentrations in dwellings up to 100 kBq/m3 were found in some special regions (i.e. Schneeberg/Saxony, Umhausen/Tyrol), where the soil shows a high uranium content and additionally, a fast radon transport in ...
G, Keller, B, Hoffmann, T, Feigenspan
openaire   +2 more sources

A Radon Exhalation Monitor

Radiation Protection Dosimetry, 1996
A radon exhalation monitor has been constructed and calibrated. The monitor is based on the adsorption of radon by active charcoal and the subsequent measurement of its γ activity by means of high resolution γ spectrometry. Exhalation rates may be determined with an accuracy of better than 20% within 48 h after exposure.
S. Oberstedt, H. Vanmarcke
openaire   +1 more source

Diffusion Model of Radon Exhalation Rates

Health Physics, 1998
Radon migration through walls is considered using an effective diffusion model. One and two dimensional models as well as a spherical geometry are compared. It is concluded that either the 1-dimensional or spherical model, both having analytical solution, may be used for practical purposes. Application is made for typical cases in Athens, Greece.
M, Antonopoulos-Domis   +2 more
openaire   +2 more sources

An International Intercomparison of Soil Gas Radon and Radon Exhalation Measurements

Health Physics, 1998
The Environmental Measurements Laboratory hosted the Sixth International Radon Metrology Programme Intercomparison Test and Workshop (IRMP6) from 12-15 June 1995. Thirty participants representing 24 different institutions from 11 countries attended. Laboratory exercises consisted of 220Rn and 222Rn concentration measurements from a source container ...
A R, Hutter, E O, Knutson
openaire   +2 more sources

Home - About - Disclaimer - Privacy