Results 61 to 70 of about 586 (176)
Proposed Method For Studying Radon Exhalation
Objective: The main objective was to test the closed radon exhalation methodology, with AlphaGuard radon detector, for different grain sizes of a granite rock sampled from central area of Belo Horizonte and propose experimental methods for its determination.
Natália Fonseca Taveira +5 more
openaire +1 more source
Artificial Neural Network Optimization to Estimate Radon in Soil
ABSTRACT Modeling and estimating radon concentration are of crucial interest to support health protection campaigns. In the literature, many studies concentrated on indoor radon, while few of them investigated the outdoor radon spatial distribution and the factors that influence its formation.
Veronica Distefano +2 more
wiley +1 more source
Radon Gas Concentrations in Soil and Radon Exhalation Rates in Thiqar City
First part to determination concentrations of Rn-222 in surface samples of soil, the highest average concentration of Rn-222 was found in AL-Refai region was equal to (127.500±2 Bq/m3), while lowest the average was found in AL-Aekeckh region which was equal to (33.750±2.2 Bq/m3), with an average value of (75.875±21.8 Bq/m3) ,while the (RER) was found ...
Nada F. Tawfiq +2 more
openaire +2 more sources
The RAD7 radon monitor, based on the electrostatic collection method, is sensitive to humidity during measurements, necessitating the use of a desiccant to maintain the relative humidity in its built-in chamber less than 10 %.
Huiying Li +10 more
doaj +1 more source
Radon-222 (222Rn) exhalation from natural and building materials is a significant source of indoor radiation exposure, yet the effects of key physical parameters controlling radon release remain insufficiently understood.
Sahar Elnobi +4 more
doaj +1 more source
Natural Radionuclides and Radon Exhalation Rate in the Soils of Cauvery River Basin
In this study, systematic measurement of activity concentrations of 40 K, 226 Ra, and 232 Th and radon exhalation rate has been done in soil samples of Cauvery River environment.
CS Kaliprasad, PR Vinutha, Y Narayana
doaj +1 more source
The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content.
M. Abo-Elmagd
doaj +1 more source
Radon exhalation rate from the latex pillows and its potential exposure to users
Objective: To develop a new system to accurately measure the radon exhalation from the latex pillows, and to estimate its potential exposure to users. Methods: The new system is composed of two loops, the first loop is designed to trap background radon ...
Phachirarat Sola +12 more
doaj +1 more source
Estimation of indoor radon levels using etched track detector
In this investigation, the activity levels of Indoor Radon-222, effective radium contents, exhalation rate of radon, and annual effective dose are reported for different indoor locations (Offices, Laboratories, Meeting rooms, and Storerooms) at two ...
Basma A. El-Badry, Tayseer I. Al-Naggar
doaj +1 more source
Gradient chamber for measuring the exhalation rate of radon and thoron from surfaces
A novel instrument (gradient chamber) and method for measuring the exhalation rates of radon (²²²Rn) and thoron (²²⁰Rn) from surfaces (e.g., soil, rocks, building materials) have been developed and tested. Determining radon and thoron exhalation rates is
Dobromir S. Pressyanov
doaj +1 more source

