Results 21 to 30 of about 5,642 (201)
The tibia is simplified as a two‐dimensional graph, The lower extremities were in an unnatural state within one year after TKA. The changes of the lower extremities force line were actually the common results of the gradual adaptation of the lower extremities to TKA and the lateral swing of the extremities 3° after surgery.
Long Cheng +6 more
wiley +1 more source
Postoperative CT scans shows component axis and three reference lines. Objective There is not a standard for rotational alignment of the tibial component in total knee arthroplasty (TKA). For now, the most commonly methods are tibial‐tubercle ‐landmark technique (TTL) and range‐of‐motion technique (ROM).
Liu Xin +5 more
wiley +1 more source
RETRACTED: The Top 50 Articles on Knee Posterolateral Corner Injuries
This article has been retracted: please see Elsevier Policy on Article Withdrawal (https://www.elsevier.com/about/ourbusiness/policies/article‐withdrawal). This article has been retracted at the request of the authors. An investigation found that the authors did not correctly retrieve the data for this review and as a result, the authors have concluded
Andre Perez‐Chaumont +4 more
wiley +1 more source
Alignment in total knee arthroplasty : what’s in a name? [PDF]
Dissatisfaction following total knee arthroplasty is a well-documented phenomenon. Although many factors have been implicated, including modifiable and nonmodifiable patient factors, emphasis over the past decade has been on implant alignment and ...
Abdel, Matthew P. +4 more
core +1 more source
We investigate the application of impaction bone grafting (IBG) combined with titanium mesh for acetabular bone defects reconstruction in revision total hip arthroplasty (THA), and follow up the clinical outcomes and imaging findings. Post‐revision radiographs show the measurement of horizontal/vertical value of the acetabular implant, acetabulum ...
Xiang Li +6 more
wiley +1 more source
Abstract Patients with neglected/missed anterior shoulder dislocation and an associated rotator cuff tear present a dilemma for the correct surgical approach that will facilitate a reduction of the dislocation and repair of the rotator cuff tear. This report describes an arthroscopic technique using standard arthroscopic portals to reduce neglected (3 ...
Dipit Sahu
wiley +1 more source
Water is a preservative of microbes
Water acts as a preservative that can to maintain the long‐term integrity and viability of microbial cells, and does this via a variety of mechanisms. Assuming that the components of the cell membrane are chemically stable, or at least repairable, and the environment is fairly constant, water molecules can apparently maintain membrane geometries over ...
John E. Hallsworth
wiley +1 more source
Bilateral C1-C2 transarticular screw and C1 laminar hook fixation and bone graft fusion for reducible atlantoaxial dislocation: a seven-year analysis of outcome. [PDF]
BACKGROUND: Bilateral C1-2 transarticular screw and C1 laminar hook fixation was developed on the basis of transarticular screws fixation. The modified technique has showed a better biomechanical stability than established techniques in previous study ...
Xiang Guo +5 more
doaj +1 more source
Vergleich verschiedener Methoden zur graphischen Darstellung der Bestimmung des anatomischen Drehzentrums der menschlichen Hüfte [PDF]
Die Implantation einer Hüfttotalendoprothese erfordert präoperativ die Festlegung der anatomisch korrekten Lage des Hüftkopfzentrums. Die bereits vor der Operation durchgeführte Messung an Beckenübersichtsröntgenaufnahmen dient als Stütze bei der ...
Griss, Peter (Prof. Dr.) +1 more
core +1 more source
Illustration of the methods of locating the acetabular centers and installing the acetabular cup. (A) Illustration of the method of locating the acetabular center. The acetabular center was located at 28.7 mm on average above the intersection point of the perpendicular bisector and acetabular anterior and posterior notches' line.
Heng Zhang +6 more
wiley +1 more source

