Results 31 to 40 of about 49,138 (166)
Strengthening of RC Column Using GFRP
Abstract: In construction industry, engineers try to find new, better, economical material. Today there are several new techniques observed in the industry. In recent years, the construction industry has seen an increasing demand to reinstate, rejuvenate, strengthen and upgrade existing concrete structures. This may be attributed to various causes such
Shubham Shukla, M. V. Waghmare
openaire +1 more source
Comparative Study Of RC Column With RC Jacketing And FRP Jacketing
Retrofitting of existing reinforced concrete (RC) structures has become increasingly essential due to ageing infrastructure, evolving seismic design requirements, and performance deficiencies identified during structural assessments. Among the various strengthening methods, RC jacketing and fibre-reinforced polymer (FRP) wrapping are two of the most ...
Rasika Varak +3 more
openaire +2 more sources
A concrete-filled steel tube (CFST) column has the advantages of high bearing capacity, high stiffness, and good ductility, while reinforced concrete (RC) structure systems are familiar to engineers.
Zhenbao Li +4 more
doaj +1 more source
To improve the mechanical behaviour of traditional reinforcement concrete (RC) column, a novel prefabricated engineered cementitious composite (ECC)–reinforced concrete composite (ECC shell–C) column was proposed in this study.
Mengjia Ding +6 more
doaj +1 more source
A unique attachment of the main reinforcements and stirrups in the column is comparatively harder than the placement of the steel tube inside the column. The replacement of reinforcements by the steel tube inside the column is economical if the volume is
Md. Foisal Haque, Ismail Hossen
doaj +1 more source
Slender reinforced concrete column may fail in material failure or instability failure. Instability failure is a common problem which cannot be analyzed with first-order analysis.
Bedaso Ahmed +2 more
doaj +1 more source
The deterioration of concrete structures might be due to ageing, poor maintenance, corrosion due to poor environmental conditions and accidental situations like earthquakes. The need to upgrade the deteriorated civil engineering infrastructure greatly enhances with the ever increasing demands. Therefore rehabilitating and retrofitting civil engineering
openaire +2 more sources
Experimental Study of Composite Hollow RC Column under Uniaxial Compressive Load
This paper presents an experimental study of the behavior of a steel-composite hollow reinforced concrete (RC) column under concentric loading. The effects of important variables, such as concrete strength, inner tube thickness, hollow ratio, column ...
Deokhee Won +3 more
doaj +1 more source
This study presents five different strengthening techniques to mitigate the axial load-carrying capacities of reinforced concrete (RC) column having mid-span transverse opening under different loading conditions. These techniques are concrete compressive
Majid Hassan +3 more
doaj +1 more source
Analytical Study on Lateral Strength of Multi-Span RC Frame with Masonry Infill
A simple and accurate analytical model for defining the lateral strength of the multi-span RC frame with masonry infill has been developed in this study.
Nugroho Fajar +3 more
doaj +1 more source