Results 91 to 100 of about 207 (123)
Some of the next articles are maybe not open access.
Journal of Investigative and Clinical Dentistry, 2018
AbstractAimIn the present study, we compared the cyclic fatigue resistance (CFR) of Reciproc Blue, WaveOne Gold, and SmartTrack files in curved artificial canals.MethodsNinety new Reciproc Blue R25, WaveOne Gold Primary, and SmartTrack X1 files were tested in artificial canals with 45° and 60° angles of curvature.
Sezer Demırbuga +1 more
exaly +4 more sources
AbstractAimIn the present study, we compared the cyclic fatigue resistance (CFR) of Reciproc Blue, WaveOne Gold, and SmartTrack files in curved artificial canals.MethodsNinety new Reciproc Blue R25, WaveOne Gold Primary, and SmartTrack X1 files were tested in artificial canals with 45° and 60° angles of curvature.
Sezer Demırbuga +1 more
exaly +4 more sources
Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments
Journal of Endodontics, 2017The aim of the present study was to compare the cyclic fatigue resistance of Reciproc Blue R25 (VDW, Munich, Germany) with Reciproc R25 (VDW) and WaveOne Gold Primary (Denstply Maillefer, Ballaigues, Switzerland).Fifteen Reciproc Blue R25, 15 Reciproc R25, and 15 WaveOne Gold Primary instruments were collected and tested in a dynamic cyclic fatigue ...
Keskin C. +3 more
openaire +2 more sources
Journal of Endodontics, 2018
The aim of the present study was to investigate the impact of ambient temperature on the life span of nickel-titanium (NiTi) files.Cyclic fatigue testing of NiTi instruments was performed in a stainless steel artificial canal. During the experiment, 4 different temperatures (0°C, 20°C, 35°C, and 39°C) were used in a thermostatic bath controlled using ...
Gianluca Plotino +8 more
openaire +3 more sources
The aim of the present study was to investigate the impact of ambient temperature on the life span of nickel-titanium (NiTi) files.Cyclic fatigue testing of NiTi instruments was performed in a stainless steel artificial canal. During the experiment, 4 different temperatures (0°C, 20°C, 35°C, and 39°C) were used in a thermostatic bath controlled using ...
Gianluca Plotino +8 more
openaire +3 more sources
Mechanical properties and metallurgical features of new and ex vivo used Reciproc Blue and Reciproc
International Endodontic Journal, 2019AbstractAimTo compare the mechanical properties and metallurgic features of new and used Reciproc Blue and Reciproc instruments.MethodologyA total of 120 R25 Reciproc Blue and R25 Reciproc instruments were used. The morphological, chemical, mechanical, thermal and phase composition characteristics of new and ex vivo used files were investigated by ...
Generali L +7 more
openaire +3 more sources
Torsional Fatigue Resistance of Blue-treated Reciprocating Instruments
Journal of Endodontics, 2018The aim of the present study was to evaluate the influence of blue thermal treatment on the torsional resistance behavior of M-Wire Reciproc files (VDW, Munich, Germany).Ten M-Wire Reciproc R25 (25/0.08v) and 10 Reciproc Blue R25 (25/0.08v, VDW) instruments were used. The torque and angle of rotation at failure of new instruments (n = 10) were measured
Emmanuel João Nogueira Leal, Silva +5 more
openaire +2 more sources
Torsional Resistance of WaveOne Gold and Reciproc Blue according to the Loading Methods
Journal of Endodontics, 2021This study aimed to compare the torsional resistances and fracture modes of WaveOne Gold (Dentsply Sirona, Ballaigues, Switzerland) and Reciproc Blue (VDW, Munich, Germany) using the repetitive torsional loading (RTL) method and the conventional single-rotation (STL) method.A 3-mm file tip was fixed with a brass plate, and a torsional load was applied ...
Sang Won Kwak +3 more
openaire +2 more sources
Assortative Mating and Reciprocal Difference in the Blue–Snow Goose Complex
Nature, 1959THE lesser snow goose Chen hyperborea and the blue goose Chen caerulescens are maintained as good species by the standard taxonomic works1 though the morphological difference between them is confined to colour of plumage. The geographical distribution of the two is different.
F G, COOCH, J A, BEARDMORE
openaire +2 more sources
Odontology, 2018
The aim was to compare the canal straightening of M-wire [Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland)] and gold- and blue-wire heat-treated [Reciproc blue (VDW) and WaveOne Gold (Dentsply Maillefer)] instruments in severely curved root canals.
Sebastian, Bürklein +2 more
openaire +2 more sources
The aim was to compare the canal straightening of M-wire [Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland)] and gold- and blue-wire heat-treated [Reciproc blue (VDW) and WaveOne Gold (Dentsply Maillefer)] instruments in severely curved root canals.
Sebastian, Bürklein +2 more
openaire +2 more sources
Medical Research Archives
Introduction: The aim of this study was to quantify the debris extruded after instrumentation with two reciprocating systems. Materials and Methods: Thirty-six mandibular premolars with a single straight root canal and apical diameter compatible with a size 15 K-file were randomly divided into two groups (n = 18) according to the instrument used: RC ...
Luana Bueno +10 more
openaire +1 more source
Introduction: The aim of this study was to quantify the debris extruded after instrumentation with two reciprocating systems. Materials and Methods: Thirty-six mandibular premolars with a single straight root canal and apical diameter compatible with a size 15 K-file were randomly divided into two groups (n = 18) according to the instrument used: RC ...
Luana Bueno +10 more
openaire +1 more source
Clinical Oral Investigations, 2018
The aim of this study was to evaluate the cyclic fatigue resistance of Reciproc and Reciproc Blue by testing in a severe apical curvature at intracanal temperature.Eighteen Reciproc R25 (25.08) and Reciproc Blue (25.08) instruments were tested in a cyclic fatigue device at body temperature (37 °C) using a stainless steel block with an artificial canal ...
Inan, Ugur +3 more
openaire +3 more sources
The aim of this study was to evaluate the cyclic fatigue resistance of Reciproc and Reciproc Blue by testing in a severe apical curvature at intracanal temperature.Eighteen Reciproc R25 (25.08) and Reciproc Blue (25.08) instruments were tested in a cyclic fatigue device at body temperature (37 °C) using a stainless steel block with an artificial canal ...
Inan, Ugur +3 more
openaire +3 more sources