Results 1 to 10 of about 175,119 (167)

E15.5 Mouse Embryo Micro-CT Using a Bruker Skyscan 1172 Micro-CT

open access: yesBio-Protocol, 2023
X-ray computed microtomography (µCT) is a powerful tool to reveal the 3D structure of tissues and organs. Compared with the traditional sectioning, staining, and microscopy image acquisition, it allows a better understanding of the morphology and a ...
Elena Astanina   +4 more
doaj   +3 more sources

Using micro computed tomographic imaging for analyzing kidney stones

open access: yesComptes Rendus. Chimie, 2021
Stone analysis is a critical part of the clinical characterization of urolithiasis. This article reviews the strengths and limitations of micro CT in the analysis of stones. Using micro CT alone in a series of 757 stone specimens, micro CT identified the
Williams, James C. Jr   +3 more
doaj   +1 more source

A comparison of micro-CT and dental CT in assessing cortical bone morphology and trabecular bone microarchitecture. [PDF]

open access: yesPLoS ONE, 2014
OBJECTIVE: The objective of this study was to evaluate the relationship between the trabecular bone microarchitecture and cortical bone morphology by using micro-computed tomography (micro-CT) and dental cone-beam computed tomography (dental CT ...
Jui-Ting Hsu   +7 more
doaj   +1 more source

Generation of Vertebra Micro-CT-like Image from MDCT: A Deep-Learning-Based Image Enhancement Approach

open access: yesTomography, 2021
This paper proposes a deep-learning-based image enhancement approach that can generate high-resolution micro-CT-like images from multidetector computed tomography (MDCT).
Dan Jin   +5 more
doaj   +1 more source

Comparison of bioimpedance spectroscopy and X-Ray micro-computed tomography for total fat volume measurement in mice. [PDF]

open access: yesPLoS ONE, 2017
Obesity and the metabolic syndrome are two pathologies whose prevalence are in a constant increase. Evaluation of the total fat mass but also of the distribution between visceral and subcutaneous adipose tissue are important factors while assessing the ...
Gaelle Aubertin   +6 more
doaj   +1 more source

The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study

open access: yesEuropean Oral Research, 2021
Purpose: The aim of this study was to evaluate the retreatment abilities of the ProTaper Next (PTN) and F6 SkyTaper (F6) systems by using micro-computed tomography (micro-ct), radiographic and microscopic imaging techniques.Materials and Methods: The ...
Esma Sarıçam   +4 more
doaj   +1 more source

Temporal and spectral imaging with micro‐CT [PDF]

open access: yesMedical Physics, 2012
Purpose:Micro‐CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro‐CT.Methods:The ...
Samuel M, Johnston   +2 more
openaire   +2 more sources

Interior micro‐CT with an offset detector [PDF]

open access: yesMedical Physics, 2014
The size of field-of-view (FOV) of a microcomputed tomography (CT) system can be increased by offsetting the detector. The increased FOV is beneficial in many applications. All prior investigations, however, have been focused to the case in which the increased FOV after offset-detector acquisition can cover the transaxial extent of an object fully ...
Kriti, Sen Sharma   +5 more
openaire   +2 more sources

Structure model index does not measure rods and plates in trabecular bone

open access: yesFrontiers in Endocrinology, 2015
Structure model index (SMI) is widely used to measure rods and plates in trabecular bone. It exploits the change in surface curvature that occurs as a structure varies from spherical (SMI = 4), to cylindrical (SMI = 3) to planar (SMI = 0).
Phil L Salmon   +5 more
doaj   +1 more source

High-definition neural visualization of rodent brain using micro-CT scanning and non-local-means processing

open access: yesBMC Medical Imaging, 2018
Background Micro-CT holds promising potential for phenotyping and histological purposes. However, few have clarified the difference in the neuroimaging quality between ex vivo and in vivo micro-CT scanners. In addition, no direct comparison has been made
Ko-Chin Chen   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy