Results 21 to 30 of about 180,705 (301)
Long-Time Evaluation of Solid-State Composite Reference Electrodes
In this study, the performance and long-time evaluation of solid-state composite (SSC) reference electrodes were investigated. The stability of all the SSC reference electrodes was continuously monitored by using potentiometry and electrochemical ...
Slim Blidi +6 more
doaj +1 more source
Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook
Novel applications of online pH determinations at temperatures from -35 °C to 130 °C in technical and biological media, which are all but ideal aqueous solutions, require new approaches to pH monitoring.
Peter Kurzweil
doaj +1 more source
Critical Review of the Use of Reference Electrodes in Li-Ion Batteries: A Diagnostic Perspective
Use of a reference electrode (RE) in Li-ion batteries (LIBs) aims to enable quantitative evaluation of various electrochemical aspects of operation such as: (i) the distinct contribution of each cell component to the overall battery performance, (ii ...
Rinaldo Raccichini +2 more
doaj +1 more source
This work summarizes the electrochemical response of a salicylic acid-based carbon electrode for use as a novel solid-state reference electrode in a redox-based pH sensor. This novel reference produces a pH insensitive response over a range of pH 3–10 in
Monica Miranda Mugica +2 more
doaj +1 more source
Fabrication of a 3D-Printed Porous Junction for Ag|AgCl|gel-KCl Reference Electrode
Fused filament fabrication (FFF) is a 3D printing method that is attracting increased interest in the development of miniaturized electrochemical sensor systems due to its versatility, low cost, reproducibility, and capability for rapid prototyping.
Sarah May Sibug-Torres +2 more
doaj +1 more source
Intense interest in reference electrode design and fabrication has recently been enriched with the application of 3D printing of electrodes with salt-loaded PVC membranes.
Bartosz Bartoszewicz +2 more
doaj +1 more source
Different types of Ag/AgCl reference electrodes have been realised by means of thin- and thick-film technique. For inner electrolyte, KCl-containing membranes have been deposited and different coatings have been used to protect the reference electrode ...
J. Schöning +3 more
doaj +1 more source
The electrical and chemical properties of the titanium dioxide (TiO2) coated spirals grown by the atomic layer deposition (ALD) technique in two different temperatures of 150 °C and 300 °C are studied. The thickness of the TiO2 layers studied are 20, 40,
Mozhdeh Nematzadeh +3 more
doaj +1 more source
Corrosion Sensor for Monitoring the Service Condition of Chloride-Contaminated Cement Mortar
A corrosion sensor for monitoring the corrosion state of cover mortar was developed. The sensor was tested in cement mortar, with and without the addition of chloride to simulate the adverse effects of chloride-contaminated environmental conditions on ...
Heng-Jing Ba, Shuang Lu
doaj +1 more source
Reference Electrode-Induced Surface Poisoning of Thin-Film Electrodes [PDF]
Abstract not Available.
Niessen, R.A.H., Notten, P.H.L.
openaire +2 more sources

