Results 21 to 30 of about 459,412 (339)

Unconventional Electrochemistry in Micro-/Nanofluidic Systems

open access: yesMicromachines, 2016
Electrochemistry is ideally suited to serve as a detection mechanism in miniaturized analysis systems. A significant hurdle can, however, be the implementation of reliable micrometer-scale reference electrodes.
Sahana Sarkar   +2 more
doaj   +1 more source

Ion selective electrodes in environmental analysis [PDF]

open access: yesJournal of the Serbian Chemical Society, 2013
An overview is given dealing with application of ion-selective electrodes (ISEs) in environmental analysis. ISEs are placed into the context of the trend of development of sensors for extensive and frequent monitoring.
Radu Aleksandar   +5 more
doaj   +1 more source

Instantaneously usable screen-printed silver/silver sulfate reference electrode with long-term stability

open access: yesElectrochemistry Communications, 2019
We developed an instantaneously usable screen-printed silver/silver sulfate (Ag/Ag2SO4) reference electrode with long-term stability. The reference electrode was composed of a Ag layer, a Ag/Ag2SO4 layer, an inner electrolyte layer, and a liquid junction
Masato Komoda   +3 more
doaj   +1 more source

Replacement of conventional reference electrode with platinum electrode for electronic tongue based analysis of dairy products

open access: yesResults in Chemistry, 2023
This work demonstrates the utility of platinum metal electrode as replacement for conventional Ag/AgCl reference electrode for voltammetric electronic tongue based analysis of edible dairy products.
Alark Shripad Kulkarni   +2 more
doaj   +1 more source

Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook

open access: yesSensors, 2009
Novel applications of online pH determinations at temperatures from -35 °C to 130 °C in technical and biological media, which are all but ideal aqueous solutions, require new approaches to pH monitoring.
Peter Kurzweil
doaj   +1 more source

Long-Time Evaluation of Solid-State Composite Reference Electrodes

open access: yesMembranes, 2022
In this study, the performance and long-time evaluation of solid-state composite (SSC) reference electrodes were investigated. The stability of all the SSC reference electrodes was continuously monitored by using potentiometry and electrochemical ...
Slim Blidi   +6 more
doaj   +1 more source

A proposal for a new type of thin-film field-emission display by edge breakdown of MIS structure [PDF]

open access: yes, 1998
A new type of field emission display(FED) based on an edge-enhance electron emission from metal-insulator-semiconductor (MIS) thin film structure is proposed.
Brodie I   +10 more
core   +2 more sources

Soft, comfortable polymer dry electrodes for high quality ECG and EEG recording [PDF]

open access: yes, 2014
Conventional gel electrodes are widely used for biopotential measurements, despite important drawbacks such as skin irritation, long set-up time and uncomfortable removal.
Boon, Paul   +9 more
core   +16 more sources

Redox cycling without reference electrodes [PDF]

open access: yesThe Analyst, 2014
The reference electrode is a key component in electrochemical measurements, yet it remains a challenge to implement a reliable reference electrode in miniaturized electrochemical sensors. Here we explore experimentally and theoretically an alternative approach based on redox cycling which eliminates the reference electrode altogether.
Sahana Sarkar   +4 more
openaire   +4 more sources

Application of the SRISM approach to the study of the capacitance of the double layer of a high density primitive model electrolyte [PDF]

open access: yes, 2011
In this study the Singlet Reference Interaction Site Model (SRISM) is employed to the study of the electrode charge dependence of the capacitance of a planar electric double layer using the primitive model of the double layer for a high density ...
Henderson, D., Woelki, S.
core   +3 more sources

Home - About - Disclaimer - Privacy