Results 211 to 220 of about 28,996 (271)

Optofluidic Raman Analysis and Capacity Recovery in Li‐ion Cells

open access: yesAdvanced Materials Technologies, EarlyView.
Operando Raman spectroscopy is used to monitor the degradation of commercial Li‐ion cells. Using a microfluidic access port, small amounts of electrolyte are sampled into a hollow‐core optical fibre, where fibre‐enhanced Raman analysis reveals Li+ solvation changes and solvent evolution.
Ermanno Miele   +9 more
wiley   +1 more source

Short-term refractive and corneal astigmatism after canal-based microinvasive glaucoma surgery. [PDF]

open access: yesPLoS One
Englisch CN   +7 more
europepmc   +1 more source

Enhanced Self‐Phase Modulation in Silicon Nitride Waveguides Integrated With 2D MoS2 Films

open access: yesAdvanced Materials Technologies, EarlyView.
ABSTRACT On‐chip integration of 2D materials provides a promising route toward next‐generation integrated optical devices with performance beyond existing limits. Here, significantly enhanced spectral broadening induced by self‐phase modulation (SPM) is experimentally demonstrated in silicon nitride (Si3N4) waveguides integrated with 2D monolayer ...
Shahaz S. Hameed   +15 more
wiley   +1 more source

New Directions in Focused Ion Beam Induced Deposition for the Nanoprinting of Functional 3D Heterostructures

open access: yesAdvanced Materials Technologies, EarlyView.
Here, it is shown that focused ion beam induced deposition (FIBID) using helium and neon ions enables advanced high‐resolution 3D nanoprinting achieving precise multimaterial architectures and engineered internal voids. Thus, FIBID with finely focused noble gas ion species is presented as a unique platform for designing functional nanomaterials for ...
Frances Isabel Allen
wiley   +1 more source

A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant

open access: yesAdvanced Materials Technologies, EarlyView.
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein   +2 more
wiley   +1 more source

Accuracy of new-generation and traditional intraocular lens power calculation formulas in pediatric primary implantation. [PDF]

open access: yesJ Cataract Refract Surg
Jin J   +8 more
europepmc   +1 more source

Tunable Extraordinary Optical Transmission in the Long‐Wavelength Infrared Range Using Electrostatic MEMS Actuation

open access: yesAdvanced Materials Technologies, EarlyView.
A MEMS‐integrated metamaterial filter enables continuous, low‐voltage spectral tuning in the long‐wavelength infrared (LWIR). The device employs extraordinary optical transmission in a dual suspended metasurface stack, where electrostatic actuation precisely controls the intermembrane air gap.
Oleg Bannik   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy