Results 51 to 60 of about 28,453 (274)
Adaptable Tile‐Based Pneumatic Origami through Structurally Coupled Localized Actuation
This article presents tile‐based pneumatic origami structures with rigid tiles and flexible fabric creases, achieving adaptable properties including morphing shape, selective multistability, and tunable stiffness. Independently pressurized folding bladders at each crease enable structurally coupled localized actuation of origami structures.
Tiantian Li, Jonathan Luntz, Diann Brei
wiley +1 more source
BackgroundMyopic corneal refractive surgery is one of the most prevalent ophthalmic procedures for correcting ametropia. This study aimed to perform a bibliometric analysis of research in the field of corneal refractive surgery over the past 40 years in ...
Fang Yang +9 more
doaj +1 more source
Confocal and Histological Features After Poly(Ethylene Glycol) Diacrylate Corneal Inlay Implantation [PDF]
Purpose: To evaluate the in vivo biocompatibility of photopolymerized poly(ethylene glycol) diacrylate (PEGDA) intrastromal inlays in rabbit corneas. Methods: Sixty-three eyes of 42 New Zealand rabbits were included.
Bidaguren, Aritz +3 more
core +2 more sources
Curvature‐tuned auxetic lattices are designed, fabricated, and mechanically characterized to reveal how geometric curvature governs stretchability, stress redistribution, and Poisson's ratio evolution. Photoelastic experiments visualize stress pathways, while hyperelastic simulations quantify deformation mechanics.
Shuvodeep De +3 more
wiley +1 more source
This study proposes a new methodology for producing metal matrix nanocomposites in the solid state. The process involves the plasma‐assisted thermochemical treatment of metallic alloy powders. As a proof‐of‐concept, TiN nanoparticles are synthesized directly on the surface of FeTi intermetallic powder particles, enabling the development of the ...
Deivison Daros Paim +4 more
wiley +1 more source
Awareness, Attitudes and Perceptions of Medical Students Towards Refractive Surgery
Purpose: To assess undergraduate medical students’ understanding of refractive surgery. Materials and Methods: A cross-sectional questionnaire-based study was conducted among undergraduate medical students at a medical college in central India.
Divya Trivedi +2 more
doaj +1 more source
Rapid and Accurate Pressure Sensing Device for Direct Measurement of Intraocular Pressure. [PDF]
PurposeIntraocular pressure (IOP) is the primary modifiable risk factor for glaucoma. Current devices measure IOP via the dynamic response of the healthy cornea and do not provide the accurate IOP measurements for patients with altered corneal ...
Camp, Andrew +4 more
core
Four‐point bending tests are conducted in an argon atmosphere on commercial MgO‐C brick grades with and without MgO‐C recyclate from room temperature up to 1300 °C. No detrimental effect of the MgO‐C recyclates on bending strength is found. Instead, a decisive influence of the total carbon content is observed, with lower total carbon contents ...
Alexander Schramm +5 more
wiley +1 more source
Intelligent radiative cooling devices, adaptable to various weather conditions, have the potential for year‐round energy savings. This study introduces a sustainable dual‐mode film made from polycaprolactone nanofibers and upcycled chip bags for effective thermal management.
Qimeng Song +4 more
wiley +1 more source
AI for a clear eye: Revolutionizing refractive surgery
Advancements in Artificial Intelligence (AI) and Machine Learning (ML) have significantly impacted the field of ophthalmology, particularly in the treatment of refractive errors and cataracts, which are major causes of treatable blindness.
John Davis Akkara
doaj +1 more source

