Results 151 to 160 of about 1,679 (172)
Some of the next articles are maybe not open access.

Current source of a FFC NMR relaxometer linearly controlled

2013 15th European Conference on Power Electronics and Applications (EPE), 2013
A Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometer combines optimized magnets (low volume and power losses) and power apparatus that integrate power supplies and control methods. The magnet of a FFC NMR relaxometer determines the requirements of the main power supply.
A. Roque   +3 more
openaire   +1 more source

A Multiple-Unit Stress Relaxometer

Textile Research Journal, 1954
The application of an improved resistance-wire strain gage [3] to a multiple-unit instrument for the measurement of stress relaxation in single fibers is described. Forces are autographically recorded with a precision and accuracy of better than 3 mg. or 1/2% of full scale.
openaire   +1 more source

Comparison of different coil topologies for an MPI relaxometer

2015 5th International Workshop on Magnetic Particle Imaging (IWMPI), 2015
Magnetic Particle Imaging (MPI) has gained a variety of potential applications since its first introduction in 2005 [1]. It offers safe tracers with applications in angiography, stem cell tracking, and cancer imaging [2]. The response of superparamagnetic iron oxide (SPIO) nanoparticles strongly affects the quality of the MPI images, which is a unique ...
Mustafa Utkur, Emine Ulku Saritas
openaire   +1 more source

Dynamic Stress Relaxometer, a New Processability Instrument

Rubber Chemistry and Technology, 1976
Abstract Increasing demands for economical, efficient, and high-production output rates require better control on processing methods in the factory. Good processing depends very much upon the uniformity of materials at each stage of the operation.
openaire   +1 more source

Digital Control of an FFC NMR Relaxometer Power Supply

2020
The fast field cycling (FFC) experimental technique allows to overcome a technical difficulty associated with the nuclear magnetic resonance (NMR) signal-to-noise ratio (SNR) at low frequency spin-lattice relaxation measurements when using conventional NMR spectrometers. Constituting a step forward than the classical analog approaches, in this paper, a
Rúben J. A. Lopes   +4 more
openaire   +1 more source

The Neuromuscular Transmission Module Versus the Relaxometer Mechanomyograph for Neuromuscular Block Monitoring

Anesthesia & Analgesia, 2002
The neuromuscular transmission module (M-NMT) is an integrated piezoelectric motion sensor module incorporated in the AS/3(TM) anesthesia monitor. We compared the neuromuscular block of 0.6 mg/kg rocuronium (twice the 95% effective dose) monitored by the M-NMT with that monitored by the Relaxometer mechanomyograph (MMG).
Ashraf A, Dahaba   +3 more
openaire   +2 more sources

Dynamic behavior of two power supplies for FFC NMR relaxometers

2012 IEEE International Conference on Industrial Technology, 2012
The main power supply of a FFC NMR relaxometer can be based on different topologies. Its design has been done having as a basic reference the parameters of a magnet specially designed and optimized, and the magnet current that is needed to achieve a magnetic induction of 0.2 T. Due to the particularities of this magnet, the FFC power supplies must have
Antonio Roque   +6 more
openaire   +1 more source

Design and construction of a high sensitivity self-shielded relaxometer

2015 5th International Workshop on Magnetic Particle Imaging (IWMPI), 2015
An MPI spectrometer [1-3] measures the harmonics generated when a nonlinear SPIO is excited by a sinusoidal field. The harmonic peak spectrum allows for comparing SPIOs spatial resolution, since the harmonics are related to the modulation transfer function of the MPI imaging PSF [4-5].
Daniel Hensley   +5 more
openaire   +1 more source

Resolving chemical shift spectra with a low-field NMR relaxometer

Chemical Physics Letters, 2004
Abstract The possibility of obtaining high-resolution NMR spectra with a relaxometer at comparatively low and weakly inhomogeneous constant magnetic field is demonstrated experimentally. By modifying the radio frequency coil to produce a linear B 1 field, apparent free induction decay signals can be observed by stroboscopic acquisition of ...
L. Grunin, B. Blümich
openaire   +1 more source

Using NMR Relaxometer in the Study of Unconventional Rocks Characteristics

SPE Russian Oil and Gas Exploration & Production Technical Conference and Exhibition, 2014
Abstract NUCLEAR MAGNETIC RESONANCE (NMR), NMR RELAXOMETER, STRUCTURE OF VOID SPACE, "FRITILLARY", "WEATHERING CRUST", "BAZHENITE" (OIL SHALES), BI-MODAL NMR DISTRIBUTION, ROUTINE CAPILLARY METHODS This paper presents the results of NMR studies of structure of void space of rocks from unconventional reservoirs.
V. Vavilin   +3 more
openaire   +1 more source