Results 91 to 100 of about 19,160 (287)

An Anterior Cingulate Cortex‐Anterior Insular Cortex Glutamatergic Circuit Gates Stress‐Induced Visceral Hypersensitivity and Anxiety via Ionotropic Glutamate Receptors Trafficking

open access: yesAdvanced Science, EarlyView.
This study identifies an anterior cingulate cortex (ACC) to anterior insular cortex (AIC) glutamatergic (Glu) circuit that gates stress induced visceral hypersensitivity and anxiety. Circuit activation induces both phenotypes, whereas inhibition relieves them.
Junwen Wang   +8 more
wiley   +1 more source

Lactate‐Driven Restriction of Mitochondrial Permeability Transition Promotes Resistance to Chemo‐Immunotherapy by Suppressing Tumor PANoptosis

open access: yesAdvanced Science, EarlyView.
Tumor‐derived lactate establishes a metabolic lock that drives chemo‐immunotherapy resistance by suppressing PANoptosis. Mechanistically, KAT8 lactylates the mitochondrial translocator ANT2, which recruits PGAM5 to dephosphorylate CypD. This cascade restricts mitochondrial permeability transition pore opening, preventing pro‐inflammatory mtDNA leakage.
Sen Zhong   +20 more
wiley   +1 more source

Multifunctional Relay Protection Device for Power Transmission Lines LIDA [PDF]

open access: yes
In the present work, the description of the multifunctional HV line protection terminal LIDA is presented. All the basic types of line protection are included in the terminal: distance protection, differential current protection, overcurrent protection ...
Leite, Lilija   +3 more
core  

Motor protection using SEL-710 microprocessor relay [PDF]

open access: yes, 2010
This paper provides details about testing a microprocessor based relays. The Relay used for testing is a microprocessor based multifunction motor protection Relay (SEL-71 0).
Kalra, Tanmay
core   +1 more source

TRANSFORMER RELAY PROTECTION IN THE RECONSTRUCTED TS BLATO [PDF]

open access: yes, 2022
U radu je prezentirana relejna zaštita energetskih transformatora općenito, uz prikaz osnovnih teoretskih podloga pojedine funkcije relejne zaštite.
Lelas, Ante
core  

Hexagonal Boron Nitride on Liquid and Single‐Crystal Copper: Operando X‐Ray and Atomistic Insights into Growth and Interfacial Structure

open access: yesAdvanced Science, EarlyView.
Liquid metal catalysts are widely assumed to promote high‐quality 2D growth. In this work, operando experiments and machine‐learning‐accelerated simulations show that hBN on Cu breaks this graphene‐derived expectation, where molten Cu promotes multilayer/3D growth, but re‐solidified single‐crystal Cu stabilizes monolayer formation.
Nikoo Ghanadan   +17 more
wiley   +1 more source

Transformer differential relay protection using SEL 587 [PDF]

open access: yes, 2011
This paper provides details about testing a microprocessor based relay. The Relay used for testing is a microprocessor based Current Differential Relay(SEL-587).
Vudayaraju, Gouthami
core   +1 more source

NIR‐II Light‐Triggered Electron Flow Initiates Cuproptosis‐Centered Thermoelectric‐Immunotherapy for Breast Cancer

open access: yesAdvanced Science, EarlyView.
A NIR‐II light‐activatable thermoelectric nanoreactor converts surface‐bound Cu2+ into bioactive Cu+ via directed electron flow. This spatiotemporally controlled reduction triggers potent cuproptosis and immunogenic cell death, eradicating primary tumors and, together with aPD‐1 therapy, suppressing metastases while establishing durable immune memory ...
Boyu Yuan   +10 more
wiley   +1 more source

Technological advance in relay protection: dangerous tendencies [PDF]

open access: yes, 2012
In the article, the modern lines in the development of relay protection are considered: complication, increasing number of functions, use of non-determined and free-programmed logic, use of Ethernet and Wi-Fi communications channels, decreasing ...
Gurevich, V. I.
core   +2 more sources

Remote intelligent test method and application of relay protection of smart substation based on autonomous controllable technology

open access: yesDiance yu yibiao
Aiming at the problems that the verification time of relay protection devices in smart substations is much longer than the planned power outage time, the workload of verification is large, and the training period of related technical personnel is long ...
MEN Qiang   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy