Results 61 to 70 of about 19,067 (286)
Desempenho da proteção diferencial em transformadores de potência perante condições especiais de operação [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia ElétricaRelés digitais vêm gradualmente substituindo os relés eletromecânicos porque são mais sensíveis, mais flexíveis e várias ...
Verney, Luiz Henrique Costa de
core
A multifunctional benzimidazole‐terminated CNF separator is constructed via a PEI‐mediated covalent locking strategy, generating dense zincophilic sites that accelerate Zn2+ transport and desolvation while enabling uniform Zn (002) deposition and suppressing side reactions.
Jie Liang +17 more
wiley +1 more source
Quantitative analysis of the influence of asymmetric channel delay on relay protection's reliability
The asymmetric delay of digital channels has negative effects on line current differential protection in a complex mechanism. Hence, it's necessary to use effective methods to improve the reliability of relay protection.
Huisheng GAO, Qing SHEN
doaj +2 more sources
The new power system puts forward higher requirements for the functionality, real-time performance and reliability of relay protection equipment. Therefore, this paper designs a monitoring platform for the operation of relay protection equipment at ...
Qingsheng Li +3 more
doaj +1 more source
Application of evolutionary algorithms for optimal directional overcurrent relay coordination
Includes bibliographical references.Relay coordination is necessary to ensure that while protection relays operate as fast as possible, they are also able to isolate only the faulted parts of the system from the network, ensuring that a power system ...
Stenane, Ndabeni Moses
core
An electrochemical platform based on differential pulse amperometry enables real‐time, selective tracking of safinamide pharmacokinetics in the living brain with high spatiotemporal resolution. When integrated with electrophysiology, this approach reveals that drug‐induced suppression of vision‐related neuronal activity provides mechanistic insight ...
Xiaoke Nan +9 more
wiley +1 more source
Current Status of Relay Protection of Mine 35 kV Power Line and Its Improvement Measures
Current status of relay protection of 35 kV power line of a mine was introduced and main problems were pointed out, namely difficult setting of protection value and matching of up-down time limit which usually lead to faults of protection failure and ...
ZHANG Zhao-hua
doaj
Innovative Practice of Protection Private Communication Network in Suzhou Electric Power Grid
【Objective】Focusing on the strategic goal of building an internationally leading energy Internet enterprise with Chinese characteristics, in accordance with the promotion of the deep integration and application of advanced information and communication ...
LAN Jian +4 more
doaj
Protection of ungrounded systems using an advanced relay element
The aim of this thesis project is to investigate single line to ground faults in an ungrounded system and determine an effective fault detection method. Ungrounded system analysis is conducted using ICAP simulation.
Siyambalapitiyage, Berty
core
The aptamer WHY‐3E identifies PrPC as a CRC driver. Stabilized by USP18, endocytosed PrPC forms a LYN/STAT3 complex, upregulating MSN transcription to promote metastasis. Crucially, WHY‐3E sensitively detects PrPC‐positive circulating exosomes, establishing a robust theoretical foundation for non‐invasive clinical diagnostics.
Chunlin Wang +23 more
wiley +1 more source