Results 71 to 80 of about 139,680 (346)
Dimethyl Fumarate, But Not Rituximab, Reduces Serum GFAP Levels and PIRMA in Relapsing–Remitting MS
ABSTRACT Objective Serum neurofilament light chain (sNfL) and glial fibrillary acidic protein (sGFAP) levels are believed to reflect mainly acute and chronic disease processes in multiple sclerosis (MS), respectively. In this study, we investigated whether dimethyl fumarate (DMF) and rituximab (RTX) differentially affect these biomarkers.
F. Shawket +14 more
wiley +1 more source
A New Tailored Sinc Pulse and Its Use for Multiband Pulse Design [PDF]
Purpose: Among RF pulses, a sinc pulse is typically used for slice selection due to its frequency-selective feature. When a sinc pulse is implemented in practice, it needs to be apodized to avoid truncation artifacts at the expense of broadening the ...
Jang-Yeon Park, Jinil Park
core +1 more source
There are numerous broadband resonance phenomena during the operation of new energy grid-connected systems. Therefore, the performance and adaptability of resonance suppression strategies for different resonance scenarios are of great significance.
Chuang Liu +4 more
doaj +1 more source
ABSTRACT Just recently, successful chimeric antigen receptor (CAR) T cell therapy was reported in the first patient with refractory, anti‐diacylglycerol lipase alpha (DAGLA) antibody‐mediated autoimmune encephalitis, achieving partial clinical remission.
Dimitrios Mougiakakos +9 more
wiley +1 more source
ABSTRACT Objectives We aimed to determine the frequency of subclinical optic nerve (ON) lesions using MRI, optical coherence tomography (OCT), and visual evoked potentials (VEP) in radiologically isolated syndrome (RIS), and to assess their diagnostic and prognostic significance.
Christine Lebrun‐Frenay +13 more
wiley +1 more source
Higher risk patient populations require continuous physiological monitoring and, in some cases, connected life-support systems, during magnetic resonance imaging examinations. While recently there has been a shift toward wireless technology, some of the
Rui Cheng +6 more
core +1 more source
ABSTRACT Objective Neurochemical levels measured by brain MR spectroscopy (MRS) have been proposed as endpoints for clinical trials in early‐stage spinocerebellar ataxia (SCA) trials. We tested their trial‐readiness by quantifying neurochemicals in three affected brain regions in early‐stage cohorts of SCA2 and SCA3, examining their reproducibility in ...
James M. Joers +19 more
wiley +1 more source
With the development of electrified railway, harmonic resonance accidents occur from time to time. Based on the mechanism of resonance, a harmonic resonance suppression radical method by impedance reshaping is proposed.
Shihui Liu +4 more
doaj +1 more source
Human Pegivirus Encephalitis With Brain Detection and Response to Sofosbuvir Ledipasvir
ABSTRACT Human pegivirus (HPgV‐1) has been associated with severe encephalomyelitis in immunocompromised patients. Its neurological spectrum remains poorly defined. We report a slowly progressive encephalitis in a person living with well‐controlled HIV, characterized by white matter abnormalities and inflammatory cerebrospinal fluid (CSF). HPgV RNA was
Antoine Moulignier +3 more
wiley +1 more source
An optimal design method of the resonant-free C-type filter
Configuring a reactive power compensation capacitors as a resonant-free C-type filter is a common method to suppress reactive power compensation capacitors resonance. It can also be used to reduce the amplification of harmonic voltage caused by resonance
XU Fangwei +5 more
doaj +1 more source

