Results 21 to 30 of about 1,817,876 (281)

In vitro study of retention forces in traditional and PEEK milled ball attachments with two retentive caps. [PDF]

open access: yesSci Rep
This in-vitro study evaluated the retention forces of traditional metal ball attachments compared with PEEK-milled ball attachments, combined with either nylon or PEEK retentive caps.
Lala S, Almustafa A, Alzoubi H.
europepmc   +2 more sources

EFFICIENCY OF RETENTION OF TWO ATTACHMENT DESIGNS USED FOR ALL ON FOUR MANDIBULAR INCLINED IMPLANTS ASSISTED OVERDENTURE [PDF]

open access: yesAlexandria Dental Journal, 2021
Introduction: Reduction of retention should be considered when selecting an attachment for inclined implants following the all-on-four concept. Aim of the study: Evaluation the retentive force of mandibular implant-assisted overdentures with two ...
Nermine El-Sehly   +3 more
doaj   +1 more source

Changes in denture retention with denture adhesives and oral moisturizers for the oral cavity: an in vitro study

open access: yesBMC Oral Health, 2021
Background It is difficult to maintain complete dentures during meals in place. This in vitro study aimed to assess changes in denture retention between rest and function using denture adhesives and oral moisturizers in an oral cavity model.
Naoya Ikemura   +7 more
doaj   +1 more source

Effect of Various Retentive Element Materials on Retention of Mandibular Implant-Retained Overdentures

open access: yesMolecules, 2022
This study aimed to examine the retentive characteristics of each retentive element material and the effects from thermocycling using the two implant-retained mandibular overdenture model.
Atitiya Chindarungruangrat   +2 more
doaj   +1 more source

Retention force measurement of telescopic crowns [PDF]

open access: yesClinical Oral Investigations, 2009
This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°.
Stefan, Bayer   +5 more
openaire   +2 more sources

An Evaluation of Retentive Ability and Deformation of Acetal Resin and Cobalt-Chromium Clasps [PDF]

open access: yesJournal of Clinical and Diagnostic Research, 2016
Aim: To compare the retentive ability and deformation of Acetal resin with Cobalt-Chromium clasps via Insertion Removal apparatus after subjecting them to stimulate clinical use.
A.Meenakshi   +4 more
doaj   +1 more source

EVALUATION OF THE RETENTION OF CONVENTIONAL VERSUS CAD/CAM FABRICATED EXTRA CORONAL ATTACHMENTS FOR REMOVABLE PARTIAL DENTURE (IN-VITRO STUDY) [PDF]

open access: yesAlexandria Dental Journal, 2023
Introduction: When treating edentulisum, severely resorbed mandibular ridges are a prevalent issue. Attachments could be used to enhance retention. For removable distal extension prosthesis, extra coronal attachments enhance retention. During mastication
Hala Selim   +2 more
doaj   +1 more source

COMPARATIVE STUDY OF BAR, POSITIONER AND BALL ATTACHMENT IN SOLITARY VERSUS SPLINTED IMPLANT ASSISTED MANDIBULAR OVERDENTURE (IN VITRO STUDY) [PDF]

open access: yesAlexandria Dental Journal, 2021
Introduction: The conventional treatment for completely edentulous patients is complete denture. But patients can have substantial difficulties using their conventional complete dentures due to a lack of retention, support, and stability and the related ...
Ahmed AbdelHakim   +2 more
doaj   +1 more source

A COMPARATIVE STUDY TO EVALUATE THE RETENTION OF CONVENTIONAL AND CAD/CAM FABRICATED BAR ATTACHMENT IMPLANT SUPPORTED ASSEMBLY (IN VITRO STUDY) [PDF]

open access: yesAlexandria Dental Journal, 2020
Introduction: The use of implant-supported overdentures is a common approach for treating edentulous mandibles. Retention and stability are provided through attachments; bar attachments being probably the most retentive due to greater mechanical ...
Aly Abdelrehim   +3 more
doaj   +1 more source

Retention force of overdenture retained with telescopic crowns: A comparison of polyether ether ketone and zirconia ceramic telescopic crowns [PDF]

open access: yesSrpski Arhiv za Celokupno Lekarstvo, 2020
Introduction/Objective. Recently, new materials for double crowns have been introduced, such as zirconia and polyether ether ketone (PEEK). However, some characteristics of these materials, such as retentive force and duration of “settling in phase ...
Milić-Lemić Aleksandra   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy