Clinical retention force development of double crowns [PDF]
This study deals with the development of the retentive forces of double crowns intraorally measured. Twenty-five combined fixed-removable prostheses with a total of 84 double crowns were included in the study. The intraoral measurement was performed at 72 defined measuring points directly adjacent to the double crowns of the dentures.
Stefan, Bayer +6 more
openaire +2 more sources
Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice.
Adityakrisna Yoshi Putra Wigianto +5 more
doaj +1 more source
In Vitro Effects of Cyclic Dislodgement on Retentive Properties of Various Titanium-Based Dental Implant Overdentures Attachment System [PDF]
The purpose of this study was to evaluate the change in the retentive forces of four different titanium-based implant attachment systems during the simulation of insert-removal cycles in an artificial oral environment. Five types of titanium-based dental
권재성 +7 more
core +2 more sources
Tensile Strength of Core Build up Material to Glass Fiber Post with Different Surface Treatment [PDF]
Aims: The purpose of this study was to investigate the effects of different surface treatments on the tensile retentive force of fiber reinforced posts (FRPs) to composite core material buildup.
Eman M. Yahya
doaj +1 more source
Wear of double crown systems: electroplated vs. casted female part
OBJECTIVES: The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (
Stefan Bayer +5 more
doaj +1 more source
Fitness accuracy and retentive forces of milled titanium clasp
Since cast titanium prostheses have many drawbacks, multi-directionally forged titanium grade 2 (MDF) was developed, and the application of the milling process was proposed for improving the titanium clasp. This in vitro study evaluated milled titanium clasps, including MDF titanium. Milling clasps were manufactured with commercially pure (CP) titanium
MARUO, Ryota +5 more
openaire +3 more sources
Purpose: The aim of this study was to establish guidelines for the selection of cast and wrought-wire clasps for removable partial dentures (RPDs) that would be appropriate for clinically encountered undercuts and facial curvatures.
C. Peter Owen, Noland Naidoo
doaj +1 more source
This study aimed to evaluate the effects of two types of provisional resin cements on the color and retentive strength of two different all-ceramic restorations cemented onto customized zirconia abutments.
Seyede Mina Salehi Dehno +3 more
doaj +1 more source
Background: Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp.
Mohamed Khaled Addas +25 more
core +1 more source
The purpose of this study was to evaluate the retentive forces over time of removable partial denture clasps fabricated by the digital method.
Vitor Anes +4 more
doaj +1 more source